User Manual
Table Of Contents
- 10 -
Chapter 5 Analysis of Common Problems
1.When using the machine, the metal shell on the surface of
the machine may be electrostatically charged and will not cause
any impact on the human body. The solution can be done by
grounding the metal of the machine housing.
2.During the printing process, the printing platform is
scraped somewhere, please make sure there is no foreign matter
under the PVC magnetic sticker.
3. If the filament can not come out normal as following reasons:
3.1 Temperature does not reach the optimum melting point of
filament. Temperature can be adjusted appropriately.
3.2 Filaments can't be supplied. After cutting out the
filaments, readjust the filaments and reprint them.
3.3 The filaments purchased are too large, to change a better
filament as 1.75mm
3.4 The nozzle might be damaged due to various reasons,
please contact customer service.
4. shifted.
4.1 Light shaft dust is too much friction, you can use paper
towels or cloth plus alcohol
Wipe to remove dust from the oil.
4.2 Check all the synchronous wheels on the optical axis and
the motor to see if there is looseness and tighten loosely.
4.3 Some customers' original pictures are scanned, and the
scanned parts have not been well processed, resulting in cura
generating Gcode not printing properly. So the scanned parts
must be processed well.