User Manual

3
ENGLISH (Original instructions)
Explanation of general view
1-1. Switch trigger
2-1. Side grip
3-1. Socket
3-2. Anvil
4-1. Socket
4-2. O-ring
4-3. Pin
5-1. Limit mark
6-1. Screwdriver
6-2. Brush holder cap
SPECIFICATIONS
Model 6905B 6906
Standard bolt M12 - M20 M16 - M22
Capacities
High tensile bolt M12 - M16 M16 - M20
Square drive 12.7 mm 19 mm
No load speed (min
-1
) 1,700 1,700
Impacts per minute 2,000 1,600
Max. fastening torque 294 N.m 588 N.m
Overall length 270 mm 327 mm
Net weight 2.8 kg 5.6 kg
Safety class /II /II
• Due to our continuing programme of research and development, the specifications herein are subject to change without notice.
• Note: Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
ENE036-1
Intended use
The tool is intended for fastening bolts and nuts.
ENF002-2
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and can
only be operated on single-phase AC supply. They are
double-insulated and can, therefore, also be used from
sockets without earth wire.
ENG905-1
Noise
The typical A-weighted noise level determined according
to EN60745:
Model 6905B
Sound pressure level (L
pA
) : 93 dB(A)
Sound power level (L
WA
) : 104 dB(A)
Uncertainty (K) : 3 dB(A)
Model 6906
Sound pressure level (L
pA
) : 98 dB(A)
Sound power level (L
WA
) : 109 dB(A)
Uncertainty (K) : 3 dB(A)
Wear ear protection
ENG900-1
Vibration
The vibration total value (tri-axial vector sum) determined
according to EN60745:
Model 6905B
Work mode : impact tightening of fasteners of the
maximum capacity of the tool
Vibration emission (a
h
) : 16.5 m/s
2
Uncertainty (K) : 1.5 m/s
2
Model 6906
Work mode : impact tightening of fasteners of the
maximum capacity of the tool
Vibration emission (a
h
) : 16.5 m/s
2
Uncertainty (K) : 2.0 m/s
2
ENG901-1
The declared vibration emission value has been
measured in accordance with the standard test
method and may be used for comparing one tool
with another.
The declared vibration emission value may also be
used in a preliminary assessment of exposure.
WARNING:
The vibration emission during actual use of the
power tool can differ from the declared emission
value depending on the ways in which the tool is
used.
Be sure to identify safety measures to protect the
operator that are based on an estimation of
exposure in the actual conditions of use (taking
account of all parts of the operating cycle such as
the times when the tool is switched off and when it
is running idle in addition to the trigger time).