Operation Manual
7
Note:
• It may take longer than the above charging time because of the optimal charging selected according to the temperature (10°C (50°F) –
40°C (104°F)), conditions of battery cartridge and maintenance charge.
Voltage 14.4 V 18 V 14.4 V 18 V Capacity (Ah)
according to
IEC61960
Charging time
(Minutes)
Number of cells 4 5 8 10
Li-ion Battery cartridge
BL1415 BL1815 — — 1.3 30
BL1415N/
BL1415NA
BL1815N — — 1.5 30
— BL1820 — — 2.0 45
— — BL1430/A BL1830 3.0 60
— — BL1440 BL1840 4.0 90