Instruction manual

8
Detach the cap (in case the metering valve is provided
with the cap).
009446
Push in the front edge.
009447
Push in the rear edge until it seats.
Inserting the fuel cell
009448
Push up and pull the fuel cover to open.
1
009449
Insert the fuel cell directing the jet nozzle of the metering
valve toward the adaptor.
009450
Insert the jet nozzle into the small hole of the adapter
properly.
009451
Put the fuel cover over the metering valve and push it
down to latch.
Adjusting the nailing depth
CAUTION:
Remove the fuel cell, the battery cartridge and nails
before adjusting the depth of nailing.
1
009456
With the hex wrench, loosen two screws and move the
contact element.
Retighten screws firmly.
Indication lamp
Color of the indication lamp means the followings.
Blinking green: Normal status
Blinking red: Need to recharge the battery cartridge
Lighting-up-red: Recharge the battery cartridge. Nailing
cannot be performed due to no remaining battery
capacity.
Blinking orange after blinking green and red
alternately: Fault detection is running. Remove and
reinsert the battery cartridge to reset. If fault detection is
running again, it is malfunction condition.
1. Screws
1. Jet nozzle