4) FIRST AID MEASURE
The product contains organic electrolyte. In case of electrolyte leakage from the battery, actions described below are required.
Eye Contact: Flush the eyes with plenty of clean water for at least 15 minutes immediately, without rubbing, and call
a doctor. If appropriate procedures are not taken, this may cause an eye irritation
Skin Contact: Wash the contact areas off immediately with plenty of water and soap. If appropriate procedures are
not taken, this may cause sores on the skin.
Inhalation: Remove to fresh air immediately, and call a doctor
5) FIRE FIGHTING MEASURES
Use specified extinguishers (gas, foam, powder) and extinguishing system under Fire Defense Law.
Since corrosive gas may be produced at the time of fire extinguishing, use an air inhalator when danger is predicted.
Use a large amount of water as supportive measure in order to get cooling effect if needed. (indoor / outdoor fire hydrant)
Carry away flammable materials immediately in case of fire.
Move batteries to a safer place immediately in case of fire.
6) ACCIDENTAL RELEASE MEASURES
Wipe off with dry cloth.
Keep away from fire
Wear safety goggles, safety gloves as needed
7) HANDLING AND STORAGE
Handling: Do not disassemble, remodel, or solder. Do not short + and - terminals with metal. Do not open the battery pack.
Storage: Store within the recommended limit of -30
o
C to 45
o
C (-22
o
F to 113
o
F), well-ventilated area. Do not expose to high
temperature (60
o
C/140
o
F). Since short circuit can cause burn hazard or safety vent to open, do not store with metal
jewelry, metal covered tables, or metal belt.
Charging: Charge within the limits of 0
o
C to 45
o
C (32
o
F to 113
o
F) temperature.
Charge with specified charger designed for this battery pack.
Discharging: Discharge within the limits of -20
o
C to 60
o
C (-4
o
F to 140
o
F) temperature.
Disposal: Dispose in accordance with applicable federal, state and local regulations.
When battery is disposed, isolate positive (+) and negative (-) terminals of the battery to avoid those terminals from
making contact with each other.
Caution: Do not incinerate. Do not disassemble. Do not expose to high temperatures (60
o
C / 140
o
F)
Do not impact, pierce or crush battery. Use specified charger only. Dispose of properly
8) EXPOSURE CONTROLS AND PERSONAL PROTECTION
In case electrolyte is leaked from battery
Acceptable concentration: Not specified in ACGIH
Facilities: Provide appropriate ventilation such as local ventilation system in the storage.
Protective Clothing: Gas mask for organic gases, safety goggle, safety glove