User's Manual

www.malags.com
28
For using the shielded antennas at longer distances from the
CUII than 4 m there is also a plastic hose of 20 m length
available. Alternatively the standard optical fibres with lengths
up to 100 m can be used.
All the fiber optic cables provided with the RAMAC/GPR are
reinforced with Kevlar? and feature stainless steel and
ceramic tip connectors. However, care should always be
exercised when handling this type of cable. The light carrying
fibre core is only 50 micrometer in diameter, which is less than
the thickness of hair.
?? Avoid excessive bending
?? Keep cables protected against physical damage
?? Keep connectors clean
7.3 Communication cable
Parallel data transfer between the RAMAC/GPR CUII and the
external PC is used as a standard.
It should be noted that data transfer is more secure with
shorter cables. For best performance use an IEEE 1284 (ECP)
compatible parallel cable that is less than or equal to three
meters long.
For configuration of external PC communication ports, see the
RAMAC GroundVision Software manual.