Owner's manual

CONNECTING T
HE
ACCEL 3-STAGE REV-LIMITER
TO AN
A
CCEL IGNITION SYSTEM
he ACCEL 3-Stage Rev-limiter uses special signals to communicate with your ignition
module, and your 3-Stage Rev-limiter can only be used with an A
CCEL ignition module.
or your rev-limiter to communicate with your ignition module
DIP-Switch-4, inside the
gnition module, must be re-set
UP.
Open the ignition module’s cover plate (the one with the wires coming through it).
Unscrew the three screws and swivel it out of the way to reveal the
DIP-Switches.
Using a small tool (A pencil is good) gently push
DIP-Switch-4 up.
Your A
CCEL ignition system’s internal
DIP-Switches are harder to access
than your rev-limiters buttons.
Set the ignition box’s rev-limit to the
highest value you ever expect to reach.
Your rev-limiter cannot override the
ignition’s designated rev-limit.
DIP-Switch-4
This A
CCEL 300+ ignition box has been
set to rev-limit an 8-cylinder
engine at 5,000 RPM.
The owner has
installed an A
CCEL
3-Stage Rev-limiter,
and has also set
DIP-Switch-4 up.
IMPORTANT POINTS TO REMEMBER
he rev-limit set inside your ACCEL ignition module is the engine’s ultimate rev-limit.
o outside control module will ever be able to override it. When setting
PEAK RPM on your
-Stage Rev-limiter it is a good idea to set it a little lower than the ignition module’s limit.
his allows you to program your A
CCEL 3-Stage Rev-limiter for its highest performance,
hile using the A
CCEL ignition module’s rev-limiter as a safety.
you remove your A
CCEL 3-Stage Rev-limiter. remember to re-set DIP-Switch-4 inside the
CCEL ignition module’s
• When connected to any control module, the ignition module’s DIP-Switch-4 must be UP.
• When not connected to a control module the ignition will not start with
DIP-Switch-4 UP
When you have adjusted DIP-Switch-4, close the cover plate and
retighten all three screws.