User's Manual

6) FN - Additional fan control settings for the humidifier
- Press SET to advance to the next setting
UP DOWN
- Press SET to confirm the setting and to advance to the next option
HE: Use this setting for electric furnaces. With this setting,
the thermostat will turn the fan on immediately with the
heating system.
HG: Use this setting for gas or oil-fired furnaces.
This setting allows the fan operation to be controlled
by the heating system; not the thermostat. This is the
correct setting for most systems.
7) SY - System (heat pump)
UP DOWN
- Press SET to confirm the setting and to advance to the next option
- Select the setting by pressing or
- Select the setting by pressing or
SY0 = NON HEAT PUMP (default) recommended
SY1 = HEAT PUMP (single-stage) not recommended with most systems
SY2 = HEAT PUMP (multi-stage) not recommended
Fn
Fn-0
Fn-1
Fn-2
Fn-3
HE/HG
HG
HE
HG
HE
Fan operation for humidifier
(default) Humidifier on will not activate the FAN
Humidifier on will not activate the FAN
Humidifier on will turn on FAN
Humidifier on will turn on FAN
Additional fan control setting for the humidifier:
36
OPTIONAL SETTINGS