User’s Manual SG300BT Wireless Handheld Linear Imager Bar code Scanner
Table of contents Table of contents ..................................... 3 INTRODUCTION .......................................... 1 CHAPTER 1 PRODUCT SAFETY ............................. 2 1.1 Safety & Caution ......................... 2 1.2 FCC Warning .............................. 3 CHAPTER 2 2.1 CHAPTER 3 GENERAL DESCRIPTION ........................ 4 Use of the SG300BT ....................... 4 INSTALLATION OF THE SG300BT ................ 5 3.1 SG300BT Unpacking ........................
4.3.1 Abort Configuration ...................... 14 4.3.2 Recall ................................... 14 4.3.3 Version Information ...................... 14 4.4 4.4.1 Cradle Interface Selection ............... 14 Interface ................................ 14 4.5 Bluetooth Scanner Setup .................. 15 4.5.1 Preface .................................. 15 4.5.2 Scanner Mode ............................. 15 4.5.
.8.3 Parity .................................... 21 4.8.4 Handshaking ............................... 22 4.9 Keyboard Wedge Mode Parameters .......... 23 4.9.1 Terminal Type ............................. 23 4.9.2 Country/Language .......................... 24 4.9.3 Upper/Lower Case .......................... 25 4.9.4 Capslock Detection ........................ 25 4.9.5 Character by ALT Method ................... 26 4.9.6 Select Numerical Pad ...................... 26 4.9.
4.14.4 Setup Code Length ........................ 38 4.15 Interleave 2 of 5 Parameters ............. 40 4.15.1 Check Digit Transmission ................. 40 4.15.2 Setup Number of Character ................ 40 4.15.3 Brazilian Banking Code ................... 40 4.15.4 Setup Code Length ........................ 41 4.16 Industrial 2 of 5 Parameters ............. 42 4.16.1 Reading Type ............................. 42 4.16.2 Check Digit Transmission ................. 42 4.16.
4.22.2 Check Digit Transmission .................. 55 4.22.3 Setup Code Length ......................... 55 4.23 GS1 Databar Omnidirectional Parameters .. 57 4.23.1 Check Digit Transmission .................. 57 4.23.2 Application ID ............................ 57 4.23.3 Symbology ID .............................. 57 4.24 GS1 Databar Limited Parameters .......... 58 4.24.1 Check Digit Transmission .................. 58 4.24.2 Application ID ............................ 58 4.24.
APPENDIXES ............................................ 72 A. Decimal Value Table ...................... 72 B. ASCII Value Table ......................... 73 C. ASCII Table .............................. 74 D. Function Key Table ....................... 80 E. Technical Specifications ................. 81 F. Scan Map ................................. 83 G. LED Indicator Status ..................... 84 H. Test Symbologies ......................... 85 Quick Configuration ........................
INTRODUCTION SG300BT is a gun-type barcode scanner which is designed specifically for retail market. To the brand new series of SG300BT, we add on more user-friendly functions with detachable interface cable that makes it easier to be operated by the customers. Speaking of the performance, this scanner supports middle to long range mode.SG300BT which supports the reading depth up to 50 centimeters, and the scan speed is up to 500 scans per second.
CHAPTER 1 1.1 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. PRODUCT SAFETY Safety & Caution Please read the following safety statement carefully. Please preserve this user’s manual for reference sometime. Before cleaning the SG300BT, the users must cut off all AC power. Do not use liquid or spray type of detersive to clean the SG300BT. Please use dampish cotton cloth to clean the SG300BT. The outlet must set nearby the SG300BT for connecting power easily. Keep the SG300BT dry to avoid short circuit.
1.2 FCC Warning This equipment complies with the requirements in Part 15 of FCC. Any operation must comply with the conditions below: (a) The equipment will not cause any severe interference. (b) The equipment can avoid any interference from environment. Statement: This product is classified as B class product. In environment this product may cause some interference. In this situation the user may do something to avoid interference.
CHAPTER 2 2.1 GENERAL DESCRIPTION Use of the SG300BT The SG300BT is very ergonomic and modern designed and very user friendly. It can be connected to your POS or Host system trough a RS232, Keyboard Wedge or USB cable. To read a bar code, simply press the red trigger button and aim the beam to the bar code. It needs to position the beam to fall across all bars in the 1D barcodes. You will hear one beep and the green LED indicator will light on after scan successfully.
CHAPTER 3 3.1 INSTALLATION OF THE SG300BT SG300BT Unpacking Unpack the SG300BT as follows: 1. Take the SG300BT and its accessories out of the box. 2. Remove the packing material. 3. Check the packing list to make sure you have received all of the items ordered. Shipment Package: a. b. c. d. e. SG300BT Linear Barcode Scanner Bluetooth Cradle Communication Cable(RS-232,keyboard wedge or USB) Power Adaptor Product Compact Disc 4.
3.2 SG300BT Cradle Installation To setup your SG300BT scanner with Bluetooth technology, please follow the steps. 1. Connect the supplied communication cable at the bottom side of the cradle. 2. Connect the other side of the communication cable to the right connector of your POS or HOST system. 3. Plug the external power supply into the power jack on the bottom of the cradle. 4. Plug the power supply into the AC outlet. 5. Turn on your POS or HOST system.
3.3 SG300BT Setup Bluetooth Communication 3.3.1 Pairing Pairing refers to when a SG300BT scanner has been linked or paired to a specific cradle by scanning that cradle’s Bluetooth MAC address code. This Bluetooth MAC address code is unique for each cradle. This address code is located on the bottom side of the cradle. The pairing of a SG300BT scanner to a cradle is one to one. Only one SG300BT scanner can be paired to a cradle at any point in time. 3.3.
ATTENTION The SG300BT scanner must be charged for a minimum of 8 hours before the scanner can be placed in full operation for the first time. The scanner LED will indicate in red when the scanner is charged. After the battery is full, the green LED on scanner will be on. The charge green LED will be off when the scanner leaving from cradle. If the battery power of the SG300BT is too low, the SG300BT will indicate red LED and beeper warning.
3.3.3 Setup SPP Slave Mode Communication To setup the communication between the SG300BT scanner and Bluetooth SPP profile application device, follow the steps. 1. The SG300BT scanner must scan “SPP Slave Mode” barcode, to set the SG300BT scanner in Slave mode. 2. When control the Bluetooth device to search the scanner, enter pin code (default 00:00:00) to setup comport. 3. When SG300BT scanner is successful connected, the scanner Blue LED will also blink followed by a long beep sound.
3.3.6 Batch Mode This batch mode is enabled when you have scanned “Batch Mode on”. The scanned data is stored in the memory of the SG300BT scanner instead of being transmitted. You can delete the last scanned bar code data by scanning “Delete Last Data” bar code. This function is disabled when you scan “Batch Mode OFF”. When scan bar code “Batch Data Output”, the stored scanned data will be immediately transmitted to the host.
CHAPTER 4 4.1 CONFIGURING THE SG300BT Preface How to configure the SG300BT? The barcode programming feature gives the possibility to change the SG300BT scanner settings with programming labels. 4.1.1 Changing Scanner Settings with Programming Codes You can setup your SG300BT by scan all necessary programming codes that meet applications. In order to change the scanner settings please follow the sequence below: 1. Power up the scanner. 2.
By scanning “Set All Default” label, the settings will go back to the factory default settings. 4.1.2 Programming Flow Chart Start Configuration Recall Parameters Interface Selection Communication Parameters Bar codes Parameters Misc. Parameters etc.
4.2 Set All Default Parameter By scanning “Set All Default” label, the all parameters will go back to the factory default settings for scanner and cradle. After reading a valid programming code the scanner will give a three high beep and the Green LED indicator will light on. Set all the parameters to the factory default settings 4.3 General Process 1 Power up the Scanner 2 Scan the Start Configuration bar code 3 Scan the bar code for the desired feature.
4.3.1 Abort Configuration Terminate current programming status. 4.3.2 Recall Replace the current parameters by the parameters saved last time 4.3.3 Version Information Display the Scanner version information and date code Display the Cradle version information and date code Display the Scanner Bluetooth MAC Address Display the Cradle Bluetooth MAC Address 4.4 CRADLE Interface Selection 4.4.
RS232 Mode USB Virtual Comport Mode 4.5 4.5.1 Bluetooth Scanner Setup Preface How to configure the Bluetooth function: The barcode programming feature gives the possibility to change the SG300BT scanner settings with programming labels. 4.5.
4.5.3 *** Batch Mode (“***” means “Quick Setting Label”, The function can be executed directly by scanning barcode instead of doing the general process.) Batch Mode ON ***Batch Data Output ***Batch Data Clear ***Delete Last Data 4.5.4 Out of Range Out of Range Disable 4.5.
Sleep Mode On 10 minute 4.6 Scanner Operation 4.6.1 Reading Mode Trigger ON/OFF Continuous/Trigger OFF Flash Auto Sence 4.6.
Low Off 4.6.3 Reading Level Bar Equals High 4.6.4 Accuracy Scan < Require 1 good decoding for a good scan> Require 2 consecutive decoding of the same bar code data for a good scan Require 3 consecutive decoding of the same bar code data for a good scan Require 4 consecutive decoding of the same bar code data for a good scan 4.6.5 Sensitivity of Continuous Reading This feature is working under Reading Continuous Mode.
Slow 4.6.6 Same Code Delay Reading Interval Following code sequences represent the length of time before a barcode can be rescanned at continuous and flash reading mode. The value can be defined from 1-50 and they represent 100ms to 5 seconds in 100ms interval. Default value is 3(0.3 second). To setup same code Delay reading interval: 1. Scan the “Begin” label 2. Go the Decimal Value Tables in Appendix B, Scan label(s),that represents the same code delay reading interval.
4.6.7 Reverse Output Characters Example: 012345 543210 Enable 4.7 RS232 Mode Parameters 4.7.
4.7.2 Data/Stop Bits The number of data/stop bits transmitted for each character 7 Data Bits < 8 Data Bits > < 1 Stop Bits > 2 Stop Bits 4.7.3 Parity A Parity bit is an extra data bit used to check data transmission errors. Even – Select to set the parity bit either 1 or 0 to ensure the number of 1. Odd – Select to set the parity bit either a 1 or 0 to ensure the number of 1. Mark – Select to set the parity bit always 1. Space– Select to set the parity bit always 0.
4.7.4 Handshaking RTS/CTS ON – Output a Request to Send (RTS) signal and wait for a Clear to Send (CTS) signal before transmitting data ACK/NAK ON – After transmitting data, wait for host to send an ACK or a NAK response. If ACK is received, then complete the data transmission. If NAK is received, re-send the last set of data and wait for ACK/NAK again. XON/XOFF ON – After transmitting data, wait for host to send an XON or a XOFF response.
4.8 Keyboard Wedge Mode Parameters 4.8.
4.8.
Portuguese Denmark Netherlands Turkey 4.8.3 Upper/Lower Case Enable Lower Case – Transmit all data as lower case Enable Upper Case – Transmit all data as upper case 4.8.
4.8.5 Character by ALT Method ALT Method Enable Send 4.8.6 Select Numerical Pad Numerical Pad ON 4.8.
100 ms 200 ms 300 ms 4.9 Output Characters 4.9.
4.10 Code Type 4.10.1 Barcode Selection If “All Bar Code ON” is selected, the scanner could read all types of bar code. If “Disable” is selected for a certain bar code type, the scanner could not read the particular bar code. The symbol of “<>” means default setting.
CODE 39 OFF Code32 / Italian Pharmacy ON Code 128 OFF Interleave 2 of 5 OFF Codabar/NW7 OFF Industrial 2 of 5 ON 29
Matrix 2 of 5 ON CODE 93 ON CODE 11 ON MSI/PLESSEY ON Telepen ON China Postage ON 30
GS1 DataBar Omnidirectional ON GS1 DataBar Expanded ON GS1 DataBar Limited ON 4.11 UPC/EAN/JAN Parameters 4.11.1 Reading Type UPC-A=EAN-13 ON Add 0 before UPC-A to make it 13 digits.
ISSN Enable Decode with Supplement Expand UPC-E Enable EAN8=EAN13 Enable GTIN Format Enable 32
4.11.2 Supplemental Setup 2 Digit Supplemental 5 Digit Supplemental 2 & 5 Digit Supplemental 4.11.
EAN-13 Check Digit Transmission OFF ISSN Check Digit Transmission OFF 4.12 4.12.1 Code 39 Parameters Type of Code Full ASCII Code 39 Italian Pharmacy/Code 32 ON 4.12.
Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit 4.12.3 Output Start/Stop Character Enable 4.12.4 Decode Asterisk Enable 4.12.5 Setup Code Length To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired set. 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read. 3. Scan the “Complete” programming code of the desired set.
Fixed Length 1st Set 1st Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin 36
Decimal Value See Appendix A Minimum Length Complete 4.13 4.13.
4.13.2 Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit and Transmit 4.13.3 Append FNC2 ON 4.13.4 Setup Code Length To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired set 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read. 3. Scan the “Complete” programming code of the desired set.
Fixed Length 1st Set 1st Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete 39
4.14 Interleave 2 of 5 Parameters 4.14.1 Check Digit Transmission Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit 4.14.2 Setup Number of Character Odd 4.14.
4.14.4 Setup Code Length To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired set 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read. 3. Scan the “Complete” programming code of the desired set. Repeat the steps 1 – 3 to set additional length.
2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete 4.15 4.15.1 Industrial 2 of 5 Parameters Reading Type IATA25 Enable 4.15.
Calculate Check Digit and Not Transmit 4.15.3 Setup Code Length To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired set 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read. 3. Scan the “Complete” programming code of the desired set. Repeat the steps 1 – 3 to set additional length.
Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete 4.16 4.16.
4.16.2 Setup Code Length To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired set 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read. 3. Scan the “Complete” programming code of the desired set. Repeat the steps 1 – 3 to set additional length.
2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete 4.17 CODABAR/NW7 Parameters Setup Start/Stop Characters upon Transmission 4.17.1 ON 4.17.
A Start A Stop B Start B Stop C Start C Stop D Start D Stop 4.17.3 Setup Code Length To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired set 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read. 3. Scan the “Complete” programming code of the desired set. Repeat the steps 1 – 3 to set additional length.
Fixed Length 1st Set 1st Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin 48
Decimal Value See Appendix A Minimum Length Complete 4.18 Code 93 Parameters 4.18.1 Check Digit Transmission Do Not Calculate Check Digit 4.18.2 Setup Code Length To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired set 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read. 3. Scan the “Complete” programming code of the desired set.
1st Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete 50
4.19 Code 11 Parameters 4.19.1 Check Digit Transmission Calculate Check 1 Digit and Transmit Calculate Check 1 Digit and Not Transmit Calculate Check 2 Digit and Transmit Calculate Check 2 Digit and Not Transmit 4.19.2 Setup Code Length To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired set 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read. 3.
Fixed Length 1st Set 1st Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete 52
4.20 MSI/Plessey Code Parameters 4.20.1 Check Digit Transmission Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit 4.20.2 Setup Code Length To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired set 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read. 3. Scan the “Complete” programming code of the desired set.
Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete 54
4.21 4.21.1 Telepen Parameters Type of Code Telepen Numeric 4.21.2 Check Digit Transmission Do Not Calculate Check Digit Calculate Check Digit and Transmit 4.21.3 Setup Code Length To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired set 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read. 3.
Fixed Length 1st Set 1st Set Begin Decimal Value See Appendix A 1st Set Complete Fixed Length 2nd Set 2nd Set Begin Decimal Value See Appendix A 2nd Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete 56
4.22 4.22.1 GS1 Databar Omnidirectional Parameters Check Digit Transmission Calculate Check Digit and Not Transmit 4.22.2 Application ID Add 01 before GS1 Databar Omnidirectional Do Not Transmit Application ID 4.22.3 Symbology ID Transmit Symbology ID Add ]e0 before GS1 Databar Omnidirectional.
4.23 4.23.1 GS1 Databar Limited Parameters Check Digit Transmission Calculate Check Digit and Not Transmit 4.23.2 Application ID Add 01 before GS1 Databar Limited. Don’t Transmit Application ID 4.23.3 Symbology ID Transmit Symbology ID Add ]e0 before GS1 Databar Limited.
4.24 4.24.1 GS1 Databar Expanded Parameters Symbology ID Transmit Symbology ID Add ]e0 before GS1 Databar Expanded.
CHAPTER 5 5.1 MISCELLANEOUS PARAMETERS Bar Code ID 5.1.1 Default Barcode ID With this function on, a leading character will be added to the output string while scanning code. User may refer to the following table to know what kind of barcode has being scanned.
Bar Code ID ON Default – Return from User Define to Default 5.1.2 User Define Code ID To set the code ID 1. Scan the symbologies programming code. 2. Go to the ASCII Table in Appendix B. Scan programming codes that represent the desired ID. Note: User define code ID will override default value. Program will not check the conflict. It is possible to have more than two symbologies which have same code ID.
CODE 128 Codabar/NW7 Interleave 2 of 5 Industrial 2 of 5 Matrix 2 of 5 CODE 93 CODE 11 China Postage MSI/PLESSEY Telepen GS1 DataBar Omnidirectional 62
GS1 DataBar Expanded GS1 DataBar Limited 5.2 Preamble and Postamble Insertion 5.2.1 Setup Insertion To set the insertion of the output characters: 1. Scan the programming code of the desired set. 2. Scan the programming code of the desired symbology 3. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the desired position to be inserted (1: the first digit, 99: the last digit). 4. Scan the “Complete” programming code of “Character Position to Be Inserted”. 5.
Code UPC-A 1st Digit Complete $ Complete End Configuration Save Parameters 5.2.
5th Set 6th Set 5.2.
Industrial 2 of 5 Matrix 2 of 5 CODE 93 CODE 11 China Postage MSI/PLESSEY Telepen GS1 DataBar Omnidirectional GS1 DataBar Expanded GS1 DataBar Limited All Codes 66
None 5.2.4 Position to Be Inserted Decimal Value See Appendix A Complete 5.2.5 Characters to Be Inserted ASCII Table See Appendix B and C Complete 5.3 Character Deletion To setup the deletion of output characters: 1. Scan the programming code of the desired set. 2. Scan the programming code of the desired symbology. 3. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the desired position to be deleted. 4.
Repeat the steps 1 – 6 to set additional deletion. Example: Delete first 3 digits Code EAN-13.
5.3.1 Deletion Set Number 1st Set 2nd Set 3rd Set 4th Set 5th Set 6th Set 5.3.
CODE 39 CODE 128 Codabar/NW7 Interleave 2 of 5 Industrial 2 of 5 Matrix 2 of 5 CODE 93 CODE 11 China Postage MSI/PLESSEY Telepen 70
GS1 DataBar Omnidirectional GS1 DataBar Expanded GS1 DataBar Limited All Codes None 5.3.3 Position to Be Deleted Decimal Value See Appendix A Complete 5.3.
APPENDIXES A.
B.
C.
DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US SPACE ! ″ # $ % & ' ( ) 75
* + , Comma Minus .
@ A B C D E F G H I Letter I J K L M N O Letter O P Q R S T U 77
V W X Y Z [ \ ] _ ^ Underscore ` a b c d e f g h i j k 78
l m n o p q r s t u v w x y z { | Vertical Slash } ~ DEL 79
D.
Up E. Down Technical Specifications Physical Characteristics: Scanner Scanner Weight Charger Weight Material Dimension Approx. 215g (include batteries) Approx. 135g (include adaptor) ABS Plastic 82.9 mm(L) x 75.0 mm(W) x 171.3 mm(H) Physical Characteristics: Bluetooth Cradle Weight Material Connector Dimension Approx 150 g ABS Plastic RJ 45C 10Pins 130.6 mm(L) x 112.2 mm(W) x 84.6 mm(H) Operational Light Source Sensor Processor Type Operating Freq.
Electrical Characteristics Scanner: Voltage Battery Charge Time Reads per Charge Scanner LED Indicator Good read Error / Alarm Bluetooth Communication Power Consumption Power On Stand by Operation Sleep Cradle: Voltage Cradle LED Indicator Good read Transmitted Success Power Consumption Power On Stand by Operation Li-Ion 3.7V/2600 mAh 5.5 hours 20,000 Times Green Red Blue 400mA 270mA 290mA 36mA 5 VDC@2A / Input AC 110-240V Green Blue 95mA 55mA 70mA Radio Characteristics Bluetooth Module Bluetooth V2.
Environmental Operating Temp. Storage Temp. Relative Humidity Ambient Light Immunity Ingress Protection 0°C to 50°C (32°F to 122°F) -20°C to 70°C (-4°F to 158°F) 20 to 95% non-condensing Scanner Drop Specification Functions normally after repeated 1.2m(4ft)drops to concrete surface Sealing IP42 10,000 LUX max @ Direct sun Light Sealed with IP42 rating protection Regulatory of Compliance FCC CE F.
G.
Cradle Indicators Status LED Buzzer Power On Red Light Continue N/A Transmitted Succeed Green Blink 1 Time N/A BT Connected BT Disconnect Blue Blink Continue Blue Blink 2 Times per Second N/A N/A H. Test Symbologies Scan one or more of these bar codes to test symbologies you enabled.
EAN 13 Interleave 2 of 5 1 234567 890128 ISBN ISSN GS1 DataBar Omnidirectional GS1 DataBar Expanded GS1 Databar Limited MSI / Plessey Matrix 2 of 5 Industrial 2 of 5 UPC A UPC E 0 Telepen 12345 67890 5 0 123456 China Postage 86 5
QUICK CONFIGURATION Start Configuration (Select your Settings) End Configuration Save Parameters Set All Defaults Recall Stored Parameters Abort Configuration Version Information 87