Vacuum Cleaner User Manual

Section 2 Installation Instructions
2-13
Changing Solution Type
CAUTION
Do not mix Cleaner and Sanitizer solutions
together. It is a violation of Federal law to use these
products in a manner inconsistent with their
labeling.
Use the following procedure to flush the system prior
to changing from Cleaner to Sanitizer or from
Sanitizer to Cleaner.
1. Remove the bottle of Cleaner or Sanitizer from
the AuCS
A. Insert a 16 oz. bottle of water.
2. Repeat the following until the water bottle is
empty (approximately 8 times):
A. Move the ice machine toggle switch to
CLEAN.
B. The water pump and dump valve will turn on.
The dump valve will shut off after
approximately 45 seconds.
C. The pump will run for 60 seconds and then
dispense for 10 seconds. (The Q1300, Q1600,
Q1800 and QDUAL will dispense for
20 seconds).
D. Move the switch to OFF after step C is
completed.
3. Install a new bottle of either Cleaner or Sanitizer
solution. Refer to “Installing Bottle of Solution”
on previous page.
Hose Priming
The dispenser pump requires priming only upon
initial installation, or if the hose between the
AuCS
A and the ice machine has been pumped dry.
WARNING
Do not blow into or suck on the hose in an attempt
to prime it.
CAUTION
Do not prime the hose until installation is complete.
Repeat the following procedure three times:
1. Move the ice machine toggle switch to CLEAN.
2. The water pump and dump valve will turn on.
The dump valve will shut off after approximately
45 seconds.
3. The control waits until the water pump runs for
60 seconds, then energizes the AuCS
A pump for
10 seconds. (The Q1300, Q1600, Q1800, and
QDUAL will energize for 20 seconds).
4. Allow the ice machine to complete the cleaning
or sanitizing cycle.
Refer to Manual Start Operation for details.
Important
The priming procedure starts the automatic
cleaning mode. Upon moving the ice machine
toggle switch to ICE, the ice machine will run
through 6 rinse cycles before making ice.