- General Information
- Installation
- Component Identification
- Maintenance
- Operation
- Blade Tower Brixing
- CEV Electronic Ice & Carbonation Control
- Flavor Magic Programming
- Flav’R-Pic External Programming
- Flav’R-Pic (FRP-250) Programming
- Flav’R-Pic (FRP-250) Brixing Procedure
- FlexTower Programming Modes
- Control Board Run or Dispense Mode
- The 6 Programming Modes on FlexTower Control Board
- To Access Programming Modes
- To Exit Programming Modes
- Manual Dispense Mode
- Timed Dispense Mode (Flavor Adder Dispensed)
- Water Calibration Mode
- Syrup Calibration Mode
- Touchpad Configuration Mode
- Touchpad LED Light Sequencing Mode (8 Selection Area Touchpad)
- Touchpad LED Light Sequencing Mode (4 Selection Area Touchpad)
- Adjustments
- Agitation Timer
- Troubleshooting
- Component Specifications
- Charts
- Diagrams
- Blade Tower Plumbing
- CEV-30i & CEV-30e Plumbing
- CEV-40i & CEV-40e Plumbing
- CT-6 Plumbing and Wiring
- CT-8 Plumbing and Wiring
- CF-1522 Plumbing
- DI-1522 Post-mix Plumbing
- DI-1522 Pre-mix Plumbing
- DI/DIL-2323 6 Valve Post-mix Plumbing
- DI/DIL-2323 8 Valve Post-mix Plumbing & Variety Valve
- DI/DIL-2323 10 Valve Post-mix Plumbing
- DI/DIL-2323 6 Valve Pre-mix Plumbing
- Flavor Magic Plumbing
- FRP-250 Plumbing Diagram
- FRP-250 & FRP-250SCI Tubing Layout
- FT-8 Plumbing
- FT-12 Plumbing
- FlexTower Water Recirculation Pump Flow
- FlexTower Water Chiller Flow
- MDH-302 12 Valve Plumbing
- MDH-402 16 Valve Plumbing
- MDH-402 20 Valve Plumbing
- S/SV150 6 Valve Diagram
- S/SV175 8 Valve Diagram
- S/SV200/250/SV-250QD 8 Valve Diagram
- S/SV200/250 10 Valve Diagram
- Flex Manifold Diagrams
- CEV Wiring
- CF Drop-In Series Wiring
- Drop-in Wiring
- Flavor Magic Wiring
- Flav’R-Pic (FRP-250) Wiring
- FlexTower Wiring
- MDH-302 & MDH-402 Wiring
- NGF-250 Wiring
- quickdraw Wiring
- S/SV/SVi Wiring
- Selectable Ice Wiring
170 Part Number STH14 9/10
FRP-250 Plumbing Diagram
C1 / C2/ NC2
S1-S8 / F1-F4
C3 / C4/ NC3
S9-S16 / F5-F8
CONTROL BOARD
LEFT SIDE
CONTROL BOARD
RIGHT SIDE
S5
S4
S9
S8
F
2
F
1
F
3
F
4
S12
F
6
F
5
F
7
F
8
S13
C1 S1 S2 S3 S6 S7 C2 NCS2
LEFT BEVERAGE VALVES RIGHT BEVERAGE VALVES
C3 NCS3 S11 S10 S15 S14 C4 S16
S1
S2
S3
S4
F
2
F
1
F
3
F
4
S6
S7S5
S8
C2 / NC2C1
LEFT TOUCHPADS
C4C3 / NC3
RIGHT TOUCHPADS
S11
S12 S10
S9 S13
S14
S15
S16
C = CARB
S = SYRUP
F = FLAVOR SHOT
NC = NON-CARB
PW = PLAIN WATER
PR = PRESSURE RELIEF
F
5
F
6
F
7
F
8
IN
CO
2
PR
OUT
TO CARB
TANK
FROM
CARB
TANK
S16 S15 S14 S13 S12 S11 S10
INTERNAL CARB
TANK (OPTIONAL)
<INLETS>
S2 S1 PW PRE-
CHILL
S9 S8 S7 S6 S5 S4 S3
PN 020001891
= WATER
= SYRUP
= FLAVOR SHOT
STH14.book Page 170 Thursday, September 23, 2010 3:35 PM