Owner's Manual

Installation - AR-10000/AR-20000 & AR-40000
Shut off the incoming water supply.
For John Guest Fitting Installation:
NOTE: Please review the following recommendations before
installing the water lines.
Tubing must be 3/8" O.D., (.371 - .376).
Cut the tube square. The outside diameter must be free of
score marks.
Burrs and sharp edges must be removed prior to installation.
NOTE: Use a tube insert for thin-walled plastic tubing.
To install water lines into the inlet/outlet ports:
1. Insert water line tubing into the inlet port fitting.
2. Pull on the tubing to be sure it is secure. If the tubing releases,
refer to the Troubleshooting section of this manual (page 11) to
reinstall.
3. Repeat for the outlet port fitting. Connect outlet water line to
the potable water connection on the ice machine.
NOTE: For water-cooled machines, be sure that the filter system
only feeds the potable water connection.
The fitting will grip before it seals. Tubing must be pushed
into the tube stop to prevent leaks.
Section 2