Instructions

6 of 6
Document Number: MSC-017 4/20
Subject: Restoring Ice Machine to Service Procedures
24. Allow clean cycle to
run.
The ice machine will
automatically run through a
wash cycle and several rinse
cycles. The entire cycle lasts
approximately 30 minutes.
Countdown clock will let
you know duration and time
remaining.
25. Press the CLEAN
button.
Follow the screen prompts
to start the sanitize cycle.
Wait until the prompt to
add sanitizer is displayed
(approximately 2 minutes)
then continue with next
step.
26. Add Manitowoc
sanitizer (9405653) to
the water trough.
Add the correct amount
of sanitizer for your model
by pouring between the
evaporator and water
curtain. The bottle is
marked with 2 oz (60ml)
graduations.
IF0300/IT0420/IT0450
IT0500/IP0500/IT0520
IF0600/IT0620/IBF0620C
IT0750/IBF0820C/IF0900/
IT0900/IT1200
3 ounces (90ml)
IBT1020C
3.5 ounces (104ml)
IT1500/IT1900/
6 ounces (180ml)
IF1400C/IF1800C/IF2100C
12 ounces (355ml)
27. Reinstall evaporator
dust cover and top
cover (when used).
Reinstall evaporator dust
cover and then reinstall top
cover.
28. Press the POWER
button.
After the sanitizing cycle is
complete, press the power
button to return to making
ice.
29. Reinstall front panel
and tighten screws.
30. Clean exterior.
Wipe surfaces with a damp
cloth rinsed in water to
remove dust and dirt from
the outside of the ice
machine.