Clearance Requirements
I0300
Self-Contained
Air-Cooled
Self-Contained
Water-Cooled
Top/Sides 40 cm (16") 20 cm (8")
Back 13 cm (5") 13 cm (5")
I0450/I0500/ I0600/
I0850/I0900/I1000/
I1100
Self-Contained
Air-Cooled
Water-Cooled or
Remote Condenser
Top/Sides 20 cm (8") 20 cm (8")
Back 13 cm (5") 13 cm (5")
I0320/I0520
Self-Contained
Air-Cooled
Self-Contained
Water-Cooled
Top/Sides 31 cm (12") 20 cm (8")
Back 13 cm (5") 13 cm (5")
I0500
230/50/1 Tropical
Rating
Self-Contained
Air-Cooled
N/A
Top 61 cm (24")
Sides/Back 31 cm (12")
I1200
Self-Contained
Air-Cooled
Water-Cooled or
Remote Condenser
Top 20 cm (8") 20 cm (8")
Sides 31 cm (12") 20 cm (8")
Back 13 cm (5") 13 cm (5")
I1400/I1800
Self-Contained
Air-Cooled
Water-Cooled or
Remote Condenser
Top/Sides 61 cm (24") 20 cm (8")
Back 31 cm (12") 13 cm (5")
I3300
Self-Contained
Water-Cooled
N/A
Top/Sides 20 cm (8")
Back 61 cm (24")
NOTE: Top air discharge kits require the same clearance
requirements as the comparable self-contained air-cooled
model.
QuietQube Model Clearance Requirements
Model Top Back Sides
I0600C - I0686C
I0870C - I0876C
I0976C
I1070C - I1076C
I1176C
I1470C - I1476C
I1870C - I1876C
I2170C - I2176C
13 cm
(5")
13 cm
(5")
13 cm
(5")
IB0690C - IB0890C - IB0896
IB1090C - IB1096
5 cm**
(2")
13 cm
(5")
20 cm**
(8")
** 61 cm (24") is recommended on top/sides for servicing
Condensing Unit Clearance Requirements
Model Top/Sides Back Front
ICVD0695 - ICVD0696
ICVD0895 - ICVD0896
ICVD0996
ICVD1095 - ICVD1096
ICVD1195- ICVD1196
ICVD1495 - ICVD1496
ICVD1895 - ICVD1896
ICVD2095 - ICVD2096
0 cm*
(0")
122 cm
(48")
122 cm
(48")
* 61 cm (24") is recommended on top/sides for servicing
,
Caution
The ice machine must be protected if it will be subjected
to temperatures below 0°C (32°F). Failure caused by
exposure to freezing temperatures is not covered by the
warranty.