Owner's Manual

14 Part Number: 000013325 Rev 02 6/17
Installation Section 2
QuietQube Head Sections
Ice Machine Voltage/Phase/Cycle Maximum Fuse/Circuit Breaker Minimum Circuit Amps Total Amps
Ice Beverage Models
115/1/60 15 amp N/A 1.1
230/1/60 15 amp N/A 1.5
All Non IB QuietQube
Models
115/1/60 15 amp 1.1 N/A
208-230/1/60 15 amp 1.1 N/A
230/1/50 15 amp 1.5 N/A
ICVD Condensing Units
Condensing Unit Voltage/Phase/Cycle
Maximum Fuse/Circuit
Breaker
Minimum Circuit
Amps
Minimum Wire Size Required
by Manitowoc
ICVD0695
208-230/1/60 15 amp 11.0 #12 Solid Copper Conductor
208-230/3/60 15 amp 7.5 #12 Solid Copper Conductor
230/1/50 15 amp 11.0 #12 Solid Copper Conductor
ICVD0696
208-230/1/60 15 amp 11.6 #12 Solid Copper Conductor
208-230/3/60 15 amp 10.2 #12 Solid Copper Conductor
230/1/50 15 amp 10.2 #12 Solid Copper Conductor
ICVD0895
208-230/1/60 20 amp 11.8 #10 Solid Copper Conductor
208-230/3/60 15 amp 9.1 #12 Solid Copper Conductor
230/1/50 20 amp 11.8 #10 Solid Copper Conductor
ICVD0896
208-230/1/60 20 amp 11.8 #10 Solid Copper Conductor
208-230/3/60 15 amp 9.1 #12 Solid Copper Conductor
230/1/50 20 amp 11.8 #10 Solid Copper Conductor
ICVD0996
208-230/1/60 20 amp 12.5 #10 Solid Copper Conductor
208-230/3/60 15 amp 9.5 #12 Solid Copper Conductor
230/1/50 20 amp 12.5 #10 Solid Copper Conductor
ICVD1095
208-230/1/60 20 amp 15.0 #10 Solid Copper Conductor
208-230/3/60 15 amp 15.0 #12 Solid Copper Conductor
230/1/50 20 amp 15.0 #10 Solid Copper Conductor
ICVD1195
208-230/1/60 25 amp 14.2 #8 Solid Copper Conductor
208-230/3/60 15 amp 9.5 #10 Solid Copper Conductor
230/1/50 35 amp 14.7 #8 Solid Copper Conductor
ICVD1195 Bristol
Compressor
208-230/1/60 25 amp 14.5 #8 Solid Copper Conductor
208-230/3/60 15 amp 9.3 #10 Solid Copper Conductor
230/1/50 35 amp 14.3 #8 Solid Copper Conductor
ICVD1495
208-230/1/60 20 amp 20.0 #10 Solid Copper Conductor
208-230/3/60 15 amp 15.0 #12 Solid Copper Conductor
230/1/50 20amp 20.0 #8 Solid Copper Conductor
ICVD1496
208-230/1/60 20 amp 11.7 #10 Solid Copper Conductor
208-230/3/60 15 amp 8.9 #12 Solid Copper Conductor
230/1/50 20 amp 11.7* #8 Solid Copper Conductor
ICVD1895
208-230/1/60 40 amp 25.0 #8 Solid Copper Conductor
208-230/3/60 25 amp 20.0 #10 Solid Copper Conductor
230/1/50 40 amp 25.0 #8 Solid Copper Conductor
ICVD2095 / ICVD2096
208-230/1/60 50 amp 40.0 #6 Solid Copper Conductor
208-230/3/60 30 amp 30.0 #10 Solid Copper Conductor
ICVD2095 & ICVD2096 Only - Verify the direction of the rotation is correct on the 3-phase scroll compressor. The ice machine will have high suction pressure, low discharge
pressure and will be noticeably loud. Reverse two incoming power leads to reverse rotation.