18 Part Number: 000013325 Rev 02 6/17
Installation Section 2
Remote Condenser and Remote Condensing Unit Refrigeration System Installation
Each ice machine head section ships from the factory with a refrigerant charge appropriate for the entire system operation. The
serial tag on the ice machine indicates the refrigerant charge.
QuietQube Models
QuietQube®
Ice Machine
Remote
Single Circuit
Condenser
Line Set*
Additional
Refrigerant
Charge for 15
to 30 Meter
Line Sets
(50’ - 100’)
I0680C
IB690C
ICVD0695
RC-26
RC-36
RC-56
680 g - 1.5 lbs
IB0686C
IB0696C
ICVD0696 680 g - 1.5 lbs
I0870C
IB0890C
ICVD0895
1814 g - 4 lbs
907 g - 2 lbs
IB0890C
I0976C
ICVD0996 907 g - 2 lbs
I1070C ICVD1095 907 g - 2 lbs
IB1090C ICVD1195 907 g - 2 lbs
I1176C ICVD1195 907 g - 2 lbs
I1470C ICVD1495 RC-25
RC-35
RC-55
907 g - 2 lbs
I1476C ICVD1495 907 g - 2 lbs
I1870C ICVD1895 907 g - 2 lbs
I2170C ICVD2095 RC-28
RC-38
RC-58
1814 g - 4 lbs
I2176C ICVD2096 1814 g - 4 lbs
I3070C ICVD3095 RC-29/39/59 1361 g - 3 lbs
*Line Set
Suction
Line
Liquid Line
Minimum Insulation
Thickness
RC 26/36/56
16 mm
5/8 inch
10 mm
3/8 inch
13 mm (1/2") Suction Line
7 mm (1/4") Liquid Line
RC 25/35/55
19 mm
3/4 inch
13 mm
1/2 inch
13 mm (1/2") Suction Line
7 mm (1/4") Liquid Line
RC 28/38/58
19 mm
3/4 inch
16 mm
5/8 inch
13 mm (1/2") Suction Line
7 mm (1/4") Liquid Line
RC 29/39/59
Two Lines
19 mm
3/4 inch
One Line
16 mm
5/8 inch
19 mm (3/4") Suction Line
7 mm (1/4") Liquid Line
n
Warning
Installation of a QuietQube® Condensing Unit may
require the use of special equipment for placement.
Trained and qualified personnel are required for proper
rigging and lifting. Holes are provided on the corners of
the condensing unit to allow the use of lifting shackles.
Important
Manitowoc remote systems are only approved and
warranted as a complete new package. Warranty on the
refrigeration system will be void if a new ice machine
head section is connected to pre-existing (used) tubing or
condensing units or vice versa.
Remote Condenser Models
Remote
Condenser Ice
Machine
Remote
Condenser
Additional Amount of
Refrigerant to Be Added to
Nameplate Charge for 15 to 30
Meter Line Sets (50’-100’)
I0590N JC0495 680 g - 1.5 lbs
I0690N JC0895 680 g - 1.5 lbs
I0890N JC0895 907 g - 2 lbs
I0996N JC0995 907 g - 2 lbs
I1090N
I1196N
JC0995 907 g - 2 lbs
I1490N JC1395 907 g - 2 lbs
I1890N JC1395 907 g - 2 lbs
Line Set Discharge Line Liquid Line Model
RT 20/35/50 12.7 mm
1/2 inch
7.9 mm
5/16 inch
I0590/I0690
I0890/I0996/
I1090/I1196
RL 20/35/50 12.7 mm
1/2 inch
9.5 mm
3/8 inch
I1490/I1890
n
Warning
Potential Personal Injury Situation
The ice machine head section contains the refrigerant
charge. Installation and brazing of the line sets must
be performed by a properly trained and EPA certified
refrigeration technician aware of the dangers of dealing
with refrigerant charged equipment.