Specification Sheet

2110 South 26th Street
Manitowoc, WI 54220
Tel: 1.920.682.0161
Fax: 1.920.683.7589
Vertical Discharge Remote Condenser
for Indigo® NXT™ Series Ice Cube Machines with R404A refrigerant
Typical Installation
Optional
34.00"
(86.36 cm)
or
38.00"
(76.20 cm)
24.50" (62.23 cm)
28.00" (71.12 cm)
29.16" (74.06 cm)
Electrica
l
Entranc
e
Discharg
e
Refrig.
Line
Liquid
Refrig.
Line
A
B
C
E
F
D
6.00" (15.24 cm)
3.50" (8.89 cm)
3.88" (9.85 cm)
12.13" (30.81 cm)
1.50" (3.81 cm)
6.50" 16.51 cm)
Optional
20.00" (50.80 c
m)
16.00" (40.64 c
m)
G
G
E
F
C
D
A
B
JCF0900 Remote Condenser
Electric
Electrical power to the remote condenser is intended to be
supplied from the ice machine; however, if necessary, a separate
electrical power source can be used.
Remote Indigo NXT Series Ice Machine
Indigo NXT Series Remote Condensers
with R404A Refrigerant
Standard Interconnecting Refrigerant Lines
Indigo
Model
Electrical
Service*
Minimum Circuit
Ampacity
Maximum
Fuse size
iF0600N 208-230/60/1 10.7 15
iF0900N 208-230/60/1 12.2 9.7 20 15
* Shaded box indicates 3 phase. Consult factory.
HACR circuit breakers can be used in place of fuses.
Condenser
Indigo
Model
Matching
Ice Machine
Condenser
Electrical
Service*
Amperage
Weight
lbs. kgs.
JCF0900
iF0600N,
iF0900N
208-230/60/1 1.0 78 35
* Consult factory. HACR circuit breakers can be used in
place of fuses.
Model
Line Length Weight
ft. m. lbs. kgs
RT-20-R404A
20 6.07 10 4.54
RT-35-R404A 35 10.67 15 6.8
RT-50-R404A 50 15.24 22 9.98
Order “RT” line sets separately for iF0600N and iF0900N
The line sets above are pre-charged and come with quick connect ttings.
www.manitowocice.com
6654 06/18