Service manual

Start-Up Section 3
3-2
Electrical Specifications
REACH-IN
REFRIGERATORS
Model Voltage/ Phase/Cycles Total
Amps
Maximum
Fuse Size
ANSI Electrical
Plug Configuration
KR-1 115/60/1 9.9 15 amp 5-15P
230/50/1 ** ** **
Full Door
KR-2 115/60/1 10.4 15 amp 5-15P
230/50/1 ** ** **
KR-3 *115 & 208-230/60/1
Minimum
circuit amps
15.1
20 amp Hard-Wired
230/50/1 ** ** **
KR-101 115/60/1 9.9 15 amp 5-15P
230/50/1 ** ** **
Half Door
KR-102 115/60/1 10.4 15 amp 5-15P
230/50/1 ** ** **
KR-103 *115 & 208-230/60/1
Minimum
circuit amps
15.1
20 amp Hard-Wired
230/50/1 ** ** **
KR-1GD 115/60/1 14.7 20 amp 5-20P
230/50/1 ** ** **
Glass Door
KR-2GD 115/60/1 16.0 20 amp 5-20P
230/50/1 ** ** **
KR-3GD *115 & 208-230/60/1
Minimum
circuit amps
15.3
20 amp Hard-Wired
230/50/1 ** ** **
REACH-IN
FREEZER
Model Voltage/ Phase/Cycles Total
Amps
Maximum
Fuse Size
ANSI Electrical
Plug Configuration
KF-1 115/60/1 12.4 20 amp 5-15P
230/50/1 ** ** **
Full Door
KF-2 115/60/1 16 20 amp 5-20-P
230/50/1 ** ** **
KF-3 *115 & 208-230/60/1
Minimum
circuit amps
15.8
20 amp Hard-Wired
230/50/1 ** ** **
KF-101 115/60/1 12.4 20amp 5-15P
230/50/1 ** ** **
Half Door
KF-201 208/230/60/1 16 20 amp 5-20-P
230/50/1 ** ** **
KF-301 *115 & 208-230/60/1
Minimum
circuit amps
15.8
20 amp Hard-Wired
230/50/1 ** ** **
* 4 wire dual voltage required: 115 Volt for the lights and fans, 208-230 Volt for the compressor.
** Data not available at time of printing.