Specifications

124 Part Number STH12 9/10
No syrup of
insufficient Syrup in
finished drink.
(continued)
Gas leak at
Syrup System.
Use a soap solution around all
connections, starting from the Low
and Medium Pressure Regulators to
the base of the Syrup Tank Plugs,
observe Quick Disconnects, Tank Cap
and Gasket, Tank Plugs and Syrup
Tank O-rings for leaks. Repair and
replace if necessary.
Syrup Filter
restricted.
Disengage Syrup Quick Disconnect
from the appropriate Syrup Tank.
Relieve pressure at the corresponding
Dispensing valve. Remove the Screw
clamp and the Filter Screen. Wash the
Filter Screen with warm water and
reassemble.
Frozen Syrup
Coil.
Refer to Troubleshooting
“Refrigeration System” under No
carbonated water at any of the
dispensing valves (Freeze up).
Dispensing
valve
inoperative.
Refer to Troubleshooting “Dispensing
Valve and Tower” under No syrup or
insufficient syrup.
Drinks too sweet. Low Pressure
Regulator
inoperative.
Verify Low Pressure Regulator set at
15 psi (1.1 kg/cm
2
). Adjust Regulator
if necessary. If Regulator will not
respond, repair or replace Regulator.
Medium
Pressure
Regulator
inoperative.
Verify Medium Pressure Regulator set
at 60 psi (4.2 kg/cm
2
). Adjust
Regulator if necessary. If Regulator
will not respond, repair or replace
Regulator.
Dispensing
valve
inoperative.
Refer to Troubleshooting “Dispensing
Valve and Tower” under Too much
syrup in finished drink.
Peculiar taste. Contaminated
Syrup.
Replace tank and sanitize the system.
Qualifier
Probable
Cause