Ice Making Sequence of Operation
INITIAL START-UP OR START-UP AFTER 
AUTOMATIC SHUT-OFF
1. Pressure Equalization
Before the compressor starts the hot gas valve is 
energized for 15 seconds to equalize pressures during 
the initial refrigeration system start-up.
2. Refrigeration System Start-Up
The compressor starts after the 15-second pressure 
equalization, and remains on throughout the entire 
Freeze and Harvest Sequences. The hot gas valve 
remains on for 5 seconds during initial compressor start-
up and then shuts off. 
At the same time the compressor starts, the condenser 
fan motor (air-cooled models) is supplied with power 
throughout the entire Freeze and Harvest Sequences. 
The fan motor is wired through a fan cycle pressure 
control, therefore it may cycle on and off. (The 
compressor and condenser fan motor are wired through 
the relay. As a result, any time the relay coil is energized, 
the compressor and fan motor are supplied with power.)
FREEZE SEQUENCE
3. Prechill
The compressor is on for 30 seconds prior to water flow 
to Prechill the evaporator. 
4. Freeze
The water pump starts after the 30-second Prechill. An 
even flow of water is directed across the evaporator and 
into each cube cell, where it freezes. 
When sufficient ice has formed, the water flow (not the 
ice) contacts the ice thickness probe. After 
approximately 7 seconds of continual water contact, the 
Harvest Sequence is initiated. The ice machine cannot 
initiate a Harvest Sequence until a 6-minute freeze time 
has been surpassed.
HARVEST SEQUENCE
5. Harvest
The water pump de-energizes stopping flow over the 
evaporator. The rising level of water in the sump trough 
diverts water out of the overflow tube, purging excess 
minerals from the sump trough. The hot gas valve also 
opens to divert hot refrigerant gas into the evaporator.
The refrigerant gas warms the evaporator causing the 
cubes to slide, as a sheet, off the evaporator and into the 
storage bin. The sliding sheet of cubes contacts the ice 
damper, opening the bin switch.
The momentary opening and re-closing of the bin switch 
terminates the Harvest Sequence and returns the ice 
machine to the Freeze Sequence (steps 3 - 4).
AUTOMATIC SHUT-OFF
6. Automatic Shut-Off
When the storage bin is full at the end of a Harvest 
Sequence, the sheet of cubes fails to clear the ice 
damper and will hold it down. After the ice damper is 
held open for 7 seconds, the ice machine shuts off. The 
ice machine remains off for 3 minutes before it can 
automatically restart.
The ice machine remains off until enough ice has been 
removed from the storage bin to allow the ice to fall clear 
of the damper. As the ice damper swings back to the 
operating position, the bin switch re-closes and the ice 
machine restarts (steps 1 - 2), provided the 3-minute 