Operation Manual
Section 3 Operation
Part Number 000001130 12/08 3-3
Energized Parts Chart
 * Condenser Fan Motor: The fan motor is wired through a fan cycle pressure control, therefore, it may cycle on and off.
CONTROL BOARD RELAYS  RELAY
12 3 3A 3BLENGTH
WATER 
PUMP
HOT GAS 
VALVE
RELAY 
COIL
COMPRESSOR
CONDENSER β 
FAN MOTOR
of βONβ TIME
INITIAL START-UP/
START UP AFTER
AUTO SHUT-OFF:
1. Pressure 
Equalization
OFF ON OFF OFF OFF
15
Seconds
2. Refrigeration 
System Start-up
OFF ON ON ON ON
5
Seconds
FREEZE 
SEQUENCE:
3. Pre-Chill
OFF OFF ON ON ON
30
Seconds
4. Freeze ON OFF ON ON ON
Until 7 sec. 
water contact 
with ice 
thickness 
probe
HARVEST 
SEQUENCE:
5. Harvest
OFF ON ON ON ON
Bin switch
activation
AUTOMATIC SHUT-
OFF:
6. Auto Shut-Off
OFF OFF OFF OFF OFF
Until
bin switch
re-closes