Service manual
Electrical System Section 6
6-44 Part No. 80-1100-3
ICE/OFF/CLEAN TOGGLE SWITCH
Function
The switch is used to place the ice machine in ICE, OFF 
or CLEAN mode of operation.
Specifications
Double-pole, double-throw switch. The switch is 
connected into a varying low D.C. voltage circuit.
Check Procedure
NOTE: Because of a wide variation in D.C. voltage, it is 
not recommended that a volt meter be used to check 
toggle switch operation.
1. Inspect the toggle switch for correct wiring.
2. Isolate the toggle switch by disconnecting all wires 
from the switch, or by disconnecting the Molex 
connector and removing wire #69 from the toggle 
switch.
3. Check across the toggle switch terminals using a 
calibrated ohm meter. Note where the wire numbers 
are connected to the switch terminals, or refer to the 
wiring diagram to take proper readings.
4. Replace the toggle switch if ohm readings do not 
match all three switch settings.
CONTROL BOARD RELAYS
Function
The control board relays energize and de-energize 
system components.
Specifications
Relays are not field replaceable. There are five relays on 
the control board:
Switch Setting Terminals Ohm Reading
ICE
66-62 Open
67-68 Closed
67-69 Open
CLEAN
66-62 Closed
67-68 Open
67-69 Closed
OFF
66-62 Open
67-68 Open
67-69 Open
Relay Controls
#1 Water Pump
#2 Water Inlet Valve
#3 Harvest Valve / HPR Valve (Remotes)
#4 Water Dump Valve
#5 Contactor (Self-Contained)
Contactor / Liquid Line Solenoid (Remotes)