Electrical System Section 6
6-50 Part No. 80-1100-3
Water Level Control Circuitry
WATER LEVEL PROBE LIGHT
The water level probe circuit can be monitored by 
watching the water level light. The water level light is on 
when water contacts the probe, and off when no water is 
in contact with the probe. The water level light functions 
any time power is applied to the ice machine, regardless 
of toggle switch position.
Figure 6-25. Freeze Cycle Water Level Setting
During the freeze cycle, the water level probe is set to 
maintain the proper water level above the water pump 
housing. The water level is not adjustable. If the water 
level is incorrect, check the water level probe for 
damage (probe bent, etc.). Repair or replace the probe 
as necessary.
WATER INLET VALVE SAFETY SHUT-OFF
In the event of a water level probe failure, this feature 
limits the water inlet valve to a six-minute on time. 
Regardless of the water level probe input, the control 
board automatically shuts off the water inlet valve if it 
remains on for 6 continuous minutes. This is important to 
remember when performing diagnostic procedures on 
the water level control circuitry.
FREEZE CYCLE CIRCUITRY
Manitowoc’s electronic sensing circuit does not rely on 
float switches or timers to maintain consistent water 
level control. During the freeze cycle, the water inlet 
valve energizes (turns on) and de-energizes (turns off) in 
conjunction with the water level probe located in the 
water trough.
During the first 45 seconds of the Freeze Cycle:
• The water inlet valve is on when there is no water in 
contact with the water level probe.
• The water inlet valve turns off after water contacts 
the water level probe for 3 continuous seconds.
• The water inlet valve will cycle on and off as many 
times as needed to fill the water trough.
After 45 seconds into the Freeze Cycle:
The water inlet valve will cycle on, and then off one more 
time to refill the water trough. The water inlet valve is 
now off for the duration of the freeze sequence.
HARVEST CYCLE CIRCUITRY
The water level probe does not control the water inlet 
valve during the harvest cycle. During the harvest cycle 
water purge, the water inlet valve energizes (turns on) 
and de-energizes (turns off) strictly by time. The harvest 
water purge adjustment dial may be set at 15, 30 or 45 
seconds.
NOTE: The water purge must be at the factory setting 
of 45 seconds for the water inlet valve to energize during 
the last 15 seconds of the Water Purge. If set at 15 or 30 
seconds the water inlet valve will not energize during the 
harvest water purge.
SV1616
15
30
45
SV1617
CONTROL BOARD
HARVEST 
WATER PURGE 
ADJUSTMENT