Service manual
Section 7 Refrigeration System
Part No. 80-1100-3 7-51
Remote Charging Procedures
1. Be sure the toggle switch is in the OFF position.
2. Close the vacuum pump valve, the low and high side 
service valves (frontseat), and the low side manifold 
gauge valve.
3. Open the charging cylinder and add the proper 
refrigerant charge (shown on nameplate) into the 
system high side (receiver outlet valve and 
discharge lines quick-connect fitting).
4. If the high side does not take the entire charge, 
close the high side on the manifold gauge set, and 
backseat (open) the low side service valve and 
receiver outlet service valve. Start the ice machine 
and add the remaining charge through the low side 
(in vapor form) until the machine is fully charged.
5. Ensure all vapor in charging hoses is drawn into the 
machine, then disconnect the manifold gauges.
NOTE: Backseat the receiver outlet service valve after 
charging is complete and before operating the ice 
machine. If the access valve core removal and 
installation tool is used on the discharge quick-connect 
fitting, reinstall the Schraeder valve core before 
disconnecting the access tool and hose.
6. Run the ice machine in freeze cycle.
7. Close the high side service valve at the ice machine.
8. Open the low side service valve at the ice machine.
9. Open the high and low side valves on the manifold 
gauge set. Any refrigerant in the lines will be pulled 
into the low side of the system.
10. Allow the pressures to equalize while the ice 
machine is in the freeze cycle.
11. Close the low side service valve at the ice machine.
12. Remove the hoses from the ice machine and install 
the caps.