Service manual
Maintenance Section 3
3-14 Part No. 80-1100-3
Water Treatment/Filtration 
GENERAL
Local water conditions may require the installation of a 
water treatment system to inhibit scale formation, filter 
out sediment, and remove chlorine taste and odor. 
Consult your local distributor for information on 
Manitowoc’s full line of NSF
-certified Tri-Liminator
filtration systems.
FILTER REPLACEMENT PROCEDURE
Tri-Liminator
 systems include a pre-filter and a primary 
filter. For maximum filtration efficiency, replace the 
primary filter cartridge every six months. If the filter 
gauge reading drops below 20 psig prior to six months 
usage, replace the pre-filter first.
1. Turn off the water supply at the inlet shutoff valve.
Figure 3-17. Typical Tri-Liminator
Water Filtration System
2. Depress the pressure release button to relieve the 
pressure.
3. Unscrew the housing from the cap.
4. Remove the used filter cartridge from the housing 
and discard it.
5. Remove the O-ring from the housing groove. Wipe 
the housing groove and the O-ring clean.
6. Lubricate the O-ring with petroleum jelly.
7. Press the O-ring into the housing groove.
8. Insert a new filter cartridge into the housing. Make 
sure it slips down over the housing standpipe.
9. Screw the housing on to the cap and carefully hand-
tighten it.
10. Repeat steps 3-9 for each filter housing.
11. Turn on the water supply to allow the housing and 
filter to slowly fill with water.
12. Depress the pressure release button to release 
trapped air from the housing.
13. Check for leaks.
CAP
CARTRIDGE
SEAL
PRESSURE 
RELEASE BUTTON
PRE-FILTER
PRIMARY 
FILTER
OUTLET SIDE
O-RING
SHUT OFF 
VALVE
SEAL
HOUSING
INLET SIDE
!
Caution
Hand-tighten only. Do not overtighten. Do not use a
spanner wrench.