Service manual
Electrical System Section 6
6-4 Part No. 80-1100-3
2. REFRIGERATION SYSTEM 
START-UP
The compressor starts after the 45-
second water purge, and it remains 
on throughout the Freeze and 
Harvest cycles.
The water fill valve is energized at 
the same time as the compressor. It 
remains on until the water level 
sensor closes for 3 continuous 
seconds.
The harvest valve(s) remains on for 
the first 5 seconds of the initial 
compressor start-up.
At the same time the compressor 
starts, the condenser fan motor (air-
cooled models) is supplied with 
power. It continues to be supplied 
with power throughout the Freeze 
and Harvest cycles.
The fan motor is wired through a fan 
cycle pressure control, and may 
cycle on and off. (The compressor 
and the condenser fan motor are 
wired through the contactor. Any time 
the contactor coil is energized, these 
components are supplied with 
power.)
Figure 6-2. Self-Contained — Refrigeration System Start-Up
Table 6-2. Self-Contained Models
2. Refrigeration System Start Up (5 Seconds)
Toggle Switch ICE
Bin Switch Closed
Control Board Relays
#1 Water Pump Open / OFF
#2 Water Fill Valve Closed / ON
#3 Harvest Solenoid Closed / ON
#4 Water Dump Valve Open / OFF
#5 Contactor Coil Closed / ON
Compressor ON
Condenser Fan Motor ON
Safety Controls (Which could stop ice machine operation)
High Pressure Cut-Out Closed
Main Fuse (On Control Board) Closed
*OVERLOAD
FAN CYCLE CONTROL
BIN SWITCH
TB35
TB33
(52)
(51)
(48)
CONTACTOR
CONTACTS
L1
(42)
(66)
(64)
ICE THICKNESS PROBE
WATER LEVEL PROBE
NOT USED
T
B35
HIGH PRES
CUTOUT
TB32
L1
(55)
RUN CAPACITOR
RUN CAPACITOR**
C
S
R
TB34
(53)
(47)
(85) (86)
COMPRESSOR
FAN MOTOR
(AIR COOLED ONLY)
R
R
(45)
(46) (50)
PTCR
BIN SWITCH LIGHT
HARVEST LIGHT/
SAFETY LIMIT CODE LIGHT
CLEAN LIGHT
WATER LEVEL
(49)
(63)
(62)
(66)
(65)
(69)
ICE
OFF
CLEAN
(67)
(68)
1F
1C
LOW D.C.
VOLTAGE
PLUG
(62)
1G
TOGGLE SWITCH
68
67
69
66
62
VIEW FOR WIRING
INTERNAL WORKING 
 VIEW
TB37
(74)
(59)
(73)
(56)
CONTACTOR
COIL
TERMINATES AT
PIN CONNECTION
TB3
0
TB3
0
TB30
TB30
L2 (N)
SEE SERIAL PLATE FOR VOLTAGE
(58)
FUSE (7A)
TRANS.
2
4
1
3
5
(61)
(60)
TB31
(76)
(98)
(57)
(99)
(75)
SOLENOID
DUMP
SOLENOID
(81)
WATER
PUMP
(77)
(80)
HARVEST
(21)
(22)
WATER
VALVE
TB30
TB30
(20)
SV1646-2