Service manual
Electrical System Section 6
6-14 Part No. 80-1100-3
Harvest Sequence
5. WATER PURGE
The water pump continues to run, 
and the water dump valve energizes 
for 45 seconds to purge the water in 
the sump trough. The water fill valve 
energizes (turns on) and de-
energizes (turns off) strictly by time. 
The water fill valve energizes for the 
last 15 seconds of the 45-second 
water purge. The water purge must 
be at the factory setting of 45 
seconds for the fill valve to energize 
during the last 15 seconds of the 
Water Purge. If set at less than 45 
seconds the water fill valve does not 
energize during the water purge.
NOTE: After the 45 second water 
purge, the water fill valve, water 
pump and dump valve de-energize. 
(Refer to โWater Purge Adjustmentโ 
on Page 3-3 for details.) The harvest 
valve and HPR solenoid also open at 
the beginning of the water purge to 
divert hot refrigerant gas into the 
evaporator.
Figure 6-12. Remote โ Water Purge
Table 6-12. Remote Models
5. Water Purge (45 Seconds)
Toggle Switch ICE
Bin Switch Closed
Control Board Relays
#1 Water Pump Closed / ON
#2 Water Fill Valve Cycles / OFF then ON
#3 Harvest Solenoid Closed / ON
Harvest Pressure Regulating (HPR) Solenoid Closed / ON
#4 Water Dump Valve Closed / ON
#5 Contactor Coil Closed / ON
Liquid Line Solenoid Energized
Compressor ON
Condenser Fan Motor ON
Safety Controls (Which could stop ice machine operation)
High Pressure Cut-Out Closed
Main Fuse (On Control Board) Closed
TERMINATES AT
PIN CONNECTION
*OVERLOAD
BIN SWITCH
ICE THICKNESS PROBE
(F1)
TB33
(52)
(51)
(48)
T
B35
L1
(42)
CONTACTOR
CONTACTS
(66)
(64)
WATER LEVEL PROBE
NOT USED
TB32
T
B35
L1
(55)
HIGH PRES
CUTOUT
(74)
(73)
REMOTE
FAN MOTOR
RUN CAPACITOR
PTCR
TB34
(53)
REMOTE CONDENSER
(F2)
(45)
TB3
0
BIN SWITCH LIGHT
HARVEST LIGHT/
SAFETY LIMIT CODE LIGHT
RUN CAPACITOR
TOGGLE SWITCH
INTERNAL WORKING 
 VIEW
CLEAN LIGHT
WATER LEVEL
(68)
ICE
C
S
R
(46)
(49)
(47)
COMPRESSOR
(62)
(66)
(69)
(67)
OFF
CLEAN
1F
LOW D.C.
VOLTAGE
PLUG
(63)
(65)
(62)
1G
1C
R
R
(50)
TB3
0
68
67
69
66
62
(56)
COIL
VIEW FOR WIRING
TB3
0
CONTACTOR
TB3
0
(57)
4
(58)
1
3
FUSE (7A)
TRANS.
5
(61)
(60)
2
HARVEST
(80)
TB31
TB37
(76)
(98)
(99)
SOLENOID
DUMP
SOLENOID
(81)
WATER
PUMP
SOLENOID
TB3
0
TB3
0
(82)
(83)
(59)
(75)
LIQUID LINE
HPR
L2 (N)
SEE SERIAL PLATE FOR VOLTAGE
(22)(21)
WATER
VALVE
(77)
(79)(78)
SOLENOID
(20)
SV1648-5