Specifications
Section 2 Installation Instructions
Part Number 000001770 06/08 2-5
Water Service/Drains
WATER SUPPLY
Local water conditions may require treatment of the 
water to inhibit scale formation, filter sediment, remove 
chlorine, and improve taste and clarity.
Follow these guidelines to install water inlet lines:
• Connect to potable water supply only.
• Do not connect the ice machine to a hot water 
supply. Be sure all hot water restrictors installed for 
other equipment are working. (Check valves on sink 
faucets, dishwashers, etc.)
• If water pressure exceeds the maximum 
recommended pressure, obtain a water pressure 
regulator from your Manitowoc distributor.
• Install a water shut-off valve for both the ice making 
and condenser water lines (if applicable).
•
Insulate water lines to prevent condensation.
DRAIN CONNECTIONS
Follow these guidelines when installing drain lines to 
prevent drain water from flowing back into the ice 
machine and storage bin:
• Drain lines must have a 2.5 cm (1 inch) drop per 1 
meter (40 inches) of run, and must not create traps.
• The floor drain must be large enough to 
accommodate drainage from all drains.
• Insulate the bin drain line to prevent condensation.
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS
1 
Min. = Minimum
2 
Max. = Maximum
3 
A 3/4” by 11-1/2 threads per inch to 14 threads per inch adapter is factory installed. Remove this adapter if 11-1/2 
threads per inch connection is desired.
Important
If you are installing a Manitowoc Tri-Liminator
water filter system, refer to the Installation
Instructions supplied with the filter system for ice
making water inlet connections.
Important
The water inlet line is connected to the water
valve. This valve is located just behind the front
panel of the ice machine.
!
Caution
Plumbing must conform to state and local codes.
Water 
Temperature
Water 
Pressure
Ice Machine 
Fitting
Tubing Size Up to Ice 
Machine Fitting
Ice Making 
Water Inlet
10?C (50?F)
Min.
1
30?C (86?F)Max.
2
240 kPA (34.8 psi)Min.
1
620 kPA (89.9 psi)Max.
2
3/4” male hose 
connection
3
0.95 cm (3/8”) minimum 
inside diameter
Ice Making/
Bin Water 
Drain
 ——  ——
1.59 cm (5/8”) 
inside 
diameter flexible 
hose
1.59 cm (5/8”) minimum 
inside diameter