Maintenance
Interior Cleaning and Sanitizing
GENERAL
Clean and sanitize the ice machine every six months for 
efficient operation. If the ice machine requires more 
frequent cleaning and sanitizing, consult a qualified 
service company to test the water quality and 
recommend appropriate water treatment.
The ice machine must be taken apart for cleaning and 
sanitizing.
CLEANING AND SANITIZING PROCEDURE
Ice machine cleaner is used to remove lime scale and 
mineral deposits. Ice machine sanitizer disinfects and 
removes algae and slime.
step 1 Set the toggle switch to the OFF position after 
ice falls from the evaporator at the end of a Harvest 
cycle. Or, set the switch to the OFF position and allow 
the ice to melt off the evaporator.
step 2 Remove all ice from the bin.
step 3 To start a cleaning cycle, move the toggle switch 
to the WASH position.
step 4 Wait until water flows over the evaporator (about 
three minutes) then add the proper amount of 
Manitowoc Ice Machine Cleaner to the water trough.
step 5 Wait until the clean cycle is complete 
(approximately 45 minutes) then place the toggle switch 
in the OFF position, disconnect power and water 
supplies to the ice machine.
step 6 Remove parts for cleaning.
A. Remove the Overflow Tube
• To remove the tube, lift it up while using a 
slight back and forth motion to loosen it from 
the drain hole.
When installing the tube, be sure it is completely 
inserted into the drain hole to prevent water leakage 
during normal operation.
Removing the Overflow Tube
B. Remove the Vinyl Hose
!
Caution
Use only Manitowoc approved Ice Machine Cleaner
(part number 94-0546-3) and Sanitizer (part
number 94-0565-3). It is a violation of Federal law
to use these solutions in a manner inconsistent with
their labeling. Read and understand all labels
printed on bottles before use.
!
Caution
Do not mix Ice Machine Cleaner and Sanitizer
solutions together. It is a violation of Federal law to
use these solutions in a manner inconsistent with
their labeling.
!
Warning
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner or
Sanitizer.
!
Caution
Never use anything to force ice from the evaporator.
Damage may result.
Model Amount of Cleaner
QM20 30 ml
!
Warning
Disconnect electric power to the ice machine at the
electric switch box before proceeding.
DRAIN
HOLE
OVERFLOW 
TUBE