User Manual

Part Number 000015236 Rev 00 11/17 11
Section 2 Installation Instructions
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS
Location
Water Temp
Min/Max
Water Pressure
Min/Max
Fitting/Min Tubing Size
Potable
Water Inlet
37°/90°F
(3°/32°C)
20/80 psi
(138/552 kPA)
3/8" FPT
Potable
Water Drain
--- --- 1/2" MPT
Condenser
Water Inlet
37°/90°F
(3°/32°C)
20/150 psi
(138/1034 kPA)
3/8" FPT
RFF2500 only = 1/2" FPT
Condenser
Water Drain
--- --- 1/2" MPT
Bin Drain --- --- 3/4" FPT
Large Capacity Bin Drain --- --- 1" FPT
UNDERCOUNTER UNITS
ROUTE
DRAIN
TUBING TO
OPEN SITE
DRAIN
WATER SHUT-OFF VALVE
REQUIRED - ICE MAKING
WATER INLET TUBING 3/8"
MIN. I.D. (.95 CM)
VENT TUBE
18" (46 CM)
LONG
ICE MAKING WATER
INLET TUBING 3/8"
MIN. I.D. (.95 CM)
VENT TUBE
18" (46 CM)
LONG
SEPARATE BIN AND ICE
MACHINE DRAINS ARE
REQUIRED
ROUTE DRAIN TUBING TO
OPEN SITE DRAIN
MODULAR UNITS
Typical Water Supply Drain Installation