MANLEY LABORATORIES, INC. OWNER'SMANUAL MANLEY 100 WATT STEREO AMPLIFIER MANLEY LABORATORIES, INC. 13880 MAGNOLIA AVE. CHINO, CA.
CONTENTS SECTION PAGE INTRODUCTION 3 MAINSCONNECTIONS 4 CONNECTINGYOURAMPLIFIER 5 BIAS PROCEDURES 6 OPERATIONAL NOTES 7 SPECIFICATIONS 8 WARRANTY 9 WARRANTY REGISTRATION 10
INTRODUCTION THANK YOU!... for choosing the Manley Euro 100 Stereo Amplifier. Designed by David Manley, the Manley Euro 100 Stereo Amplifier uses only the best available components, with the shortest and cleanest signal path possible, and with the use of our own milling equipment we can provide you with a amplifier that looks as good as it sounds. For this amplifier design, we have chosen an interesting Russian military tube, the GammaY50.
MAINS CONNECTIONS Your amplifier has been factory set to the correct mains voltage for your country. The voltage setting is marked on the serial badge, located on the rear panel. Check that this complies with your local supply. Export units for certain markets have a moulded mains plug fitted to comply with local requirements. If your unit does not have a plug fitted the coloured wires should be connected to the appropriate plug terminals in accordance with the following code.
CONNECTING YOUR AMPLIFIER Setting up your amplifier is rather easy. 1. Connect all source components (turntable, CD, Tuner, Tape DAT, etc.) to your preamplifier. 2. Connect the interconnects from the output of the preamplifier or switching center to the RCA input on the top rear of the amplifier. 3. Connect the hot or "+" speaker cable to the red binding post and the common or "" speaker cable to the black binding post (See diagarm 2).
BIAS PROCEDURES The Manley Euro Stereo 100 is a fixed bias system that requires very little attention. If you wish to adjust or check the bias, follow the following steps. 1. On diagram 2, which depicts the top panel of the amplifier, you can see 4 black tip jacks and 1 green tip jack.
OPERATIONAL NOTES SWITCHING ON The power switch is located on the lower left hand corner of the front panel. Push the top of the rocker switch (1) to turn on the amplifier and the bottom of the rocker to turn off the amplifier. The LED on the right side of the front panel will illuminate indicating that the amplifier is operating. RUNNING It is not recommended that you leave your amplifier permanently switched on. This only wastes electricity and tube life.
SPECIFICATIONS Vacuum Tubes: 4 x ΓY50 (Output), 2 x 6350 (Driver), 2 x 12AT7 (Input) Output Power 88 Watts @1Khz 1.5%THD, into 5 ohms Frequency Response, +/- .
WARRANTY All Manley Laboratories equipment is covered by a limited warranty against defects in materials and workmanship for a period of 90 days from date of purchase to the original purchaser only. A further optional limited 5 year warranty is available to the original purchaser upon proper registration of ownership within 30 days of date of first purchase.
WARRANTY REGISTRATION We ask that you please fill out this registration form and send the bottom half to: MANLEY LABORATORIES REGISTRATION DEPARTMENT 13880 MAGNOLIA AVE. CHINO CA, 91710 Registration entitles you to product support, full warranty benefits, and notice of product enhancements and upgrades. You MUST complete and return the following to validate your warranty and registration. Thank you again for choosing to use Manley Laboratories. MODEL ____________________ SERIAL No.