MANLEY LABORATORIES, INC. OWNER'SMANUAL LANGEVIN 150 WATT DUALMONOBLOCK AMPLIFIER MANUFACTURED BY: MANLEY LABORATORIES, INC. 13880 MAGNOLIA AVE. CHINO, CA.
CONTENTS SECTION PAGE INTRODUCTION 3 MAINS CONNECTIONS 4 CONNECTING YOUR AMPLIFIER 5 REAR PANEL 6 OPERATIONAL NOTES 7 SPECIFICATIONS 8 WARRANTY 9 WARRANTY REGISTRATION 10 NOTES 11
INTRODUCTION THANK YOU!... for choosing Manley Laboratories' Langevin 150 Watt Solid State Amplifier. Designed around the concept that less is more, the Langevin 150 Watt Solid State Amplifier uses the best available parts with the shortest, cleanest, signal path possible. With the use of our own C.N.C. milling machine, we can provide you with a superb sounding machine with elegant packaging.
MAINS CONNECTIONS The Manley Laboratories' Langevin 150 Watt Solid State Amplifier requires a significant amount of AC current to operate properly. For best operation, plug the amplifier directly into the wall outlet, avoiding extension cords and other devices which restrict the current supply to amplifier. If extension cables are required, be certain that they are high quality, heavy duty (14-12 guage) cables. Your amplifier has been factory set to the correct mains voltage for your country.
CONNECTING YOUR AMPLIFIER Setting up your amplifier is rather easy. 1. Connect all source components (turntable, CD, Tuner, Tape DAT, etc.) to your preamplifier. 2. Connect the interconnects from the output of the preamplifier or switching center to RCA input. 3. Connect the hot or "+" speaker cable to the top binding post and the common or "-" speaker cable to the bottom binding post (See diagarm III). Ensure that the other end of the cable is connected correctly to the speaker.
REAR PANEL A IEC MAINS CONNECTOR Standard mains connector. Connect an IEC mains cable to a 50/60 Hz AC receptacle. B MAINS FUSE Use a 3 amp (110, 120 mains voltage) or a 2 amp (220, 240 voltage) SLO-BLO fuse. C GROUND BINDING POSTS Use to connect Chassis ground (Black) to Circuit Ground (Green) D RAIL FUSES Use only a 5 Amp FAST BLOW fuse in each voltage rail. E OUTPUT BINDING POST (-) Negative or common speaker terminal binding post.
OPERATIONAL NOTES SWITCHING ON With monoblocks we suggest that you turn on one amplifier first allowing about thirty seconds to pass before powering the other. Also, ALWAYS turn ON your preamplifier or console FIRST and let this settle before turning on the amplifiers. RUNNING It is not recommended that you leave your amplifier permanently switched on. This only wastes electricity. Your amplifier uses all solid state components and reaches peak operating condition in approximately 30 minutes.
SPECIFICATIONS Output Power 20 Hz - 20 KHz, 8 Ohm Load 4 Ohm Load 130 Watts .15% T.H.D. 225 Watts .15% T.H.D. Input Sensitivity 1 Volt Input Impedance 49 Kohm Output Impedance < 1 Ohm Power Consumption 50 W Quiescent 360 W Peak (4 ohm) 250 W Peak (8 ohm) Mains Fuse 100, 110, 120V 220, 240 V Dimensions Weight (Each channel) (Each channel) = 5A (Slo-Blo) = 3A (Slo-Blo) W=9.5, D=12.7, H=3.50 inches 20 lbs.
WARRANTY All Manley Laboratories equipment is covered by a limited warranty against defects in materials and workmanship for a period of 90 days from date of purchase to the original purchaser only. A further optional limited 5 year warranty is available to the original purchaser upon proper registration of ownership within 30 days of date of first purchase.
WARRANTY REGISTRATION We ask that you please fill out this registration form and send the bottom half to: MANLEY LABORATORIES REGISTRATION DEPARTMENT 13880 MAGNOLIA AVE. CHINO CA, 91710 Registration entitles you to product support, full warranty benefits, and notice of product enhancements and upgrades. You MUST complete and return the following to validate your warranty and registration. Thank you again for choosing to use Manley Laboratories. MODEL ____________________ SERIAL No.