Datasheet

DPM-3232
Digital DC Power Meter with Data logging capability
User Manual
Introduction
As a digital DC power meter, it measures the real time DC Voltage (5-60V), DC Current (0-60A), Watt, and it
also displays the Amp-hour, Watt-hour, Max. Watt, running time when Power Meter has been connected, the
maximum & minimum values of voltage and current during the measuring period. There is one pair of leads
for source input and another pair for load output, the power meter can either be powered by the input or the
output which ever has a minimum 5V DC. The Power Meter can also be powered by an external DC voltage
of 5 to 60V DC if DC voltage range of 0-60V is desired.
Once the Power Meter is powered up it starts to data logged Amp hour, Watt-hour, Max. & Min. Voltage &
Current values at selectable interval from 30 seconds to 3 minutes.
Up to 1,500 sets of data are stored in the Power Meter Memory (EEPROM) even when the Power Meter is
off power. The data can be retrieved by a PC using our optional Data adapter (USB type) and software
program.
The last set of data such as Ah, Wh, Max. current, Max. Watt, (and sometimes Max. and Min. Voltage) can
be displayed when only either the source or the load is connected to a dc source of 5 to 60V.
The power supply can either be mounted to the Snap-On bracket or any ferrous metal surface magnetically.
Precaution
a. Do not exceed 60A and 60V DC in application of DC Meter.
b. Do not apply 60A DC more than 5 second and non-repeatable within 60 second
c. This meter is designed and made for indoor use only.
d. Do not disassemble or attempt to repair the power meter.
e. If Startup screen does not appear, immediate remove the power sources.
f. It is a good practice to have either input or output terminal connected on the supplied terminal block to
prevent short circuited.
g. Double check on the correct polarity. If either input or output connection is in wrong polarity, there is no
display on LCD.
h. Damage to the Power Meter may result if wrong polarity power is applied.
i. Never short leads connected to either set of leads.
j. Do not exert pressure on the display to avoid damage to LCD display.
Controls and Indicators
FRONT
1. Arrow Mark to show Input (Source) leads
2. LCD Display : Constant displays: V, A, and W.
Scrolling displays : Amp Hour, Watt Hour and Max. Watt Hour, Max. & Min. Current, Voltage and total
time Power Meter connected.
3. Arrow Mark to show Output (Load) leads
4. Scrolling display : Any one of the scrolling displays can be stopped at your desired display
(and released) by one quick press of the "Reset" button (9)

Summary of content (7 pages)