Owner`s manual

Charger Operation
figure 02: PFC-50 Layout
Turning the Charger On and Off
There is an ON/OFF Breaker to the left of the blue user control panel at the top of
the charger. This breaker is the main switch to turn the charger on or off. If ever
there is a concern while charging first shut off this breaker switch.
NOTICE! DO NOT unplug the blue SB-175 Anderson connectors (DC line) from
your charger while it is charging! If the battery pack is disconnected while the
charger is putting out power the charger can be damaged. Failure to heed these
warnings may result in significant internal damage to the charger which is not
covered under your warranty!
4