EZwarePlus Programming Manual 113
1010-1015, Rev. 03
6. Disable buzzer: When checked, the HMI will not sound the buzzer (beep) when the screen is touched.
Local Bit LB9019 can be used to control the buzzer. Set the bit to disable the buzzer and clear the bit
to enable the buzzer.
7. Prohibit remote HMI connecting this machine: When checked, the HMI will not allow connections
from a remote HMI. Local Bit LB9044 can be used to control remote connections. Set the bit to
disallow remote connections, clear the bit to allow remote connections.
This setting controls whether or not other HMIs can connect to this HMI. It does not affect how
this HMI connects to other HMIs.
8. Disable upload function (effective after rebooting HMI): When checked, prevents the project from
being uploaded from the HMI (sets LB9033 ON). Reports “error: uploading /mt8000/001/mt8000.”
9. Prohibit password remote-read operation: When checked, a remote HMI cannot read from the local
words containing the Project and User password data (sets LB9053 ON).
10. Prohibit password remote-write operation: When checked, a remote HMI cannot write to the local
words containing the Project and User password data (sets LB9054 ON).
11. Use a disconnection icon on relative objects when PLC communication fails: When checked, any
object that cannot be resolved due to communication loss will be displayed with a special icon:
12. VNC server: Check Password from project to use the password entered in the adjacent Password box
for a VNC client to use to connect to the HMI’s internal VNC server. When not checked, use the VNC
password entered in the HMI’s System Settings VNC Server Setting tab.
The VNC Server Password is stored in Local Words LW9530-9537.
13. VNC Server: Check Monitor Mode to allow VNC Client(s) to connect to the HMI, but not allow the
client(s) to change any data.
This setting is also controlled by Local Bit LB12088.
14. LW protection: When checked, remote HMI(s) are prevented from writing to the range of Local Word
addresses specified in the LW range boxes.
15. RW protection: When checked, remote HMI(s) are prevented from writing to the range of Recipe
Word addresses specified in the RW range boxes.
16. EasyAccess server: Check Login EasyAccess server to enable EasyAccess in the HMI. See Technical
Note 5082, “Using EasyAccess” for more information.