Specifications

23G-Series RO System
3024270 Rev G 11 14Oct13
1.8 Environmental Requirement
Minimum Maximum
Ambient Temperature 4°C (39°F) 32°C (90°F)
Storage Temperature 2°C (36°F) 32°C (90°F)
Altitude N/A 10,000 feet
CAUTION:
This equipment must not be allowed to freeze. Irreparable harm to
various components, including RO membranes may result.
NOTE:
The user/operator should recognize that moisture can be caused by
condensation and is not necessarily an equipment leak. This equipment
will function properly in the presence of condensation.
1.9 Specifications for 23G Machines
1.9.1 RO Feedwater Specifications
The rated flow for all machines in this section is based upon the
following feedwater specifications. Limits should not be exceeded
without consulting the factory.
Inlet Pressure
6
Rated; 30 psi (2.1 bar)
Maximum; 60 psi (4.1 bar)
Minimum; 20 psi (1.4 bar)
Temperature
1
35-77F (2-25C) not to exceed 85F (29C)
Langelier Saturation Negative 0.1
Index of Concentrate
2
Continuous Free Chlorine (mg/L)
3
Less than 0.1 ppm
Silt Density Index
4
Less than 3
Iron 0 ppm
Other Impurities
5
Pre-filter 5 micron cartridge(s)