Specifications
23G-Series RO System
3024270 Rev G 30 14Oct13
4.0 ECM-100 OPERATION
4.1 ECM-100 General Description of Operation
The ECM-100 is a state-of-the-art electronic controller/monitor designed
for 23G machines. The ECM-100 controls and monitors machine
operation including operating performance. Data is stored automatically by
the ECM-100 at preset run-time intervals and can be downloaded to a
printer or PC port via a RS-232 communication port.
4.2 ECM-100 Displays and Controls
The ECM-100 displays and controls are as follows (Reference Figure 4.5):
4.2.1 System Status Lights - Left Column
Machine On Indicates that the machine is either
running or is in standby mode.
Alarm Indicates an alarm condition.
Tank Full Indicates that a signal from a tank level
control has put the machine in standby
mode.
Pretreatment Lockout Indicates that a signal from pretreatment
equipment has put the machine in
standby mode.
Permeate Divert Indicates that the permeate is being
diverted to drain.
4.2.2 System Status Lights - Right Column
RO Pump On Indicates RO pump (main high-pressure
pump) should be running.
CIP Pump On Indicates CIP pump should be running.
Autoflush Indicates the Autoflush valve should be
open.