Specifications
23G-Series RO System
3024270 Rev G 36 14Oct13
05 Log Tables
The Log Tables Menu allows the user to display and download
historical machine operational data.
Press ENTER to view the data tables. Use the ARROW keys to
advance through the data tables. Enter the passcode to download
the data tables to a printer or computer starting with the table in
view on LCD. Three pages (up to 400 lines) of historical data will be
downloaded. Use the DOWN ARROW key to advance to and
download older data tables, if desired, before exiting the log tables
menu. Repeating the download sequence twice will download the
entire historical record log (up to 10 weeks of data recorded: this is
adjustable to one reading per hour during a 40 hour work week).
06 Calibration
The Calibration Menu should be used to change/modify calibration
parameters for sensors (flow, temperature, conductivity) and
transducers (pressure).
Press ENTER to select and advance through the list. Enter the
passcode to change a calibration parameter value. Use the
ARROW keys to raise or lower the calibration value, then press
ENTER to store and advance to the next parameter. When all
calibration numbers have been entered, the ECM-100 will
automatically return to the default menu.
NOTE:
When performing the two-point pH calibration, the passcode must be entered
immediately prior to adjusting the calibration number for each pH CAL LOW and
pH CAL HIGH. The passcode must be entered even if you have already entered
the code to adjust a calibration number or parameter earlier in the list (this is to
prevent inadvertent loss of pH calibration while viewing the calibration
parameters). Be sure to store the Factory Settings (Maintenance Menu 11) after
calibrating the pH probe.
07 Maintenance
The Maintenance Menu is used to gain access to all general
operational conditions/functions (menu options 08-13).
Press ENTER to select. Use the UP ARROW key to advance
through the maintenance functions. Press ENTER to select a
function.