Specifications
23G-Series RO System
3024270 Rev G 39 14Oct13
4.3.1 Selecting Parameters and Changing Settings
To select a parameter:
1. Scroll through the parameters using the ARROW keys until the
desired parameter is shown on the LCD screen.
2. Press the ENTER key.
3. Scroll through the settings using the ARROW keys, until the
desired setting is displayed on the LCD screen.
To change a setting:
1. Enter the passcode.
2. Raise or lower (toggle between) settings, using the ARROW
keys.
3. Once the desired setting is shown on the LCD screen, press
ENTER to store and advance.
4. Press ESC to cancel or change and ECS again to return to the
default screen.
4.3.2 Responding to an Alarm
When the machine alarm is indicated by the ECM-100 controller, a
signal is transmitted from the base unit to the ECM-100. An audible
alarm will sound, the large alarm light will turn on, and a small
alarm light (corresponding to the appropriate alarm condition) will
identify the alarm. The mute button on the unit will silence the alarm
horn, but the horn will reactivate if a new alarm condition is
indicated. The alarm light will turn off and horn will silence
automatically when the alarm conditions clear.
Pressing the Alarm Bypass key will add one minute to the
shutdown delay timer to allow time for remedy (the alarm continues
to sound, but the machine will not shutdown until after the delay).