Specifications
23G-Series RO System
3024270 Rev G 71 14Oct13
6. Apply a small amount of water-soluble lubricant to the
outside surface area of all O-rings installed on the
adapters.
CAUTION: Do not use petroleum jelly or other petroleum based material
as they may damage elastomer and/or thermoplastic.
Figure 5.9.2 Membrane Element Installation P/N 3027262
7. Determine the direction of feed flow in the membrane
element housing. Be sure to look at the “Direction of
Flow” arrow on each membrane element housing;
they may be different within a given machine. Be sure
element direction of flow matches housing direction of
flow on the plastic component.
8. The open side of the U-cup concentrate seal must be
placed at the end of the membrane element housing
closest to the housing feed port/connection.
Victaulic Clamp
Victaulic Gasket
Endcap Assembly
W/Load Transfer Device
New O-Rings (2)
New O-Ring
Adapter 3027177
Product
Concentrate U-cup Seal (Brine Seal)
ADAPTER 3027177 PLUG
New O-Rings
Membrane Element
Housing
Direction of Flow