24. TROUBLESHOOTING
FAULT DISPLAY
PROBLEM
SOLUTION
CODE
If no buttons are pressed within 120 seconds, the programming mode
terminates automatically.
OPEN and CLOSED door positions programmed without passing the
reference point.
7
8
NOTICE:
The operator displays the system fault(s) automatically one at a time as follows:
Fault 1
System Fault Display: (Example - Error Code 7)
Note: The last system fault code can be viewed by pressing the “P” button once. To return to operation mode press “-” or “+” button.
7
8
7
Rational speed sensor
impulse not present,
operator system is
obstructed.
Have operator serviced *
Have operator serviced *
Have operator serviced *
9
The door does not move
easily or is obstructed.
The maximum driving power has been set too low.
Have maximum driving power checked by specialist *
10
Excess travel stop.
11
15
16
The current sensor for the
automatic cut-out is
defective.
Photo eye sensors not
connected properly.
Photo eye sensors not
aligned.
Obstruction in the door
path (photo eye beam
broken).
Check photo eye sensors wiring and connections.
Realign photo eye sensors.
Remove obstruction from door path.
26
Have the outlet assigned for the operator and/or
supplied power checked.
Operator system
overloaded.
28
Reset the bus modules
Have the connected bus modules checked.
Check door for obstructions, proper manual operation,
proper balance, or broken springs. Clear obstructions or
have door serviced, If needed.
Have the operating sensitivity settings checked by
an authorized dealer/installer.
MS bus fault
Door movement too
stiff or irregular.
Door blocked.
Operator operating
sensitivity set too
sensitive (low).
30
9
10
11
15
16
26
28
30
Adjustments setting
interrupted before
completion.
Door can be operated normally. Recheck
adjustments if adjustment settings were not
completed. Refer to page 18.
Have operator serviced *