Instructions / Assembly

15
8-13. INSTALL WALL CONTROL PANEL
8-14. CONNECTING WIRES TO OPERATOR
The control panel must be mounted inside the garage within sight
of the garage door, clear of all moving garage door parts or any
associated parts - and at least 5 feet (1.5m) above the floor to
prevent the use of these controls by children. The device should
only be used when the door is in clear sight of the user and the
door area is free of people or any obstructions.
Attach 2-conductor wire to the screw terminal on back of
control panel. See Fig. 34 (Back). White wire attaches to
terminal #3 screw, white wire with color stripes attaches to
terminal #4 screw.
Position wall control panel onto wall in desired location.
Mark hole location on wall.
Drill 1/16” pilot holes into wall.
Insert and tighten screws to secure control panel to wall.
Make sure wiring is routed out from behind control through
one of the cutouts to avoid pinching the wires.
Route wires along wall use staples (provided) to secure
wiring to wall. Do NOT punch wire. Drive staples with only
enough force to hold wiring in place.
If mounting to drywall instead of wood, drill 3/16” pilot holes and
use anchors provided. If mounting to electrical box that is prewired
for this purpose, mount directly to box with proper screws provided.
Separate the double wire from each photo eye into two single
wires: the white wire and the white wire with red stripes.
Combine the white wires from each photo eye and twist
stripped ends together tightly.
Insert stripped end of white wire combination into terminal
block hole #1.
Repeat procedure for the white wires with red stripes except
insert them into terminal hole #2.
Separate the double wire from wall control into two single
wires: the white wire and the white wire with black stripes.
Insert stripped end of white wire into terminal block hole #3.
Insert stripped end of white wire with black stripes into terminal
block hole #4.
Connect terminal block with attached wires to control unit,
see Fig. 35, 38.
For reference see wiring diagram Fig. 39.
See Fig. 34A.
Fig. 34
Fig. 35
Screw caps
4
3
To Terminal #4 Screw
To Terminal #3 Screw
Fig. 34B
Fig. 34A
Multiple Wall Control (Fig. 34B):
Multiple wall controls may be installed in parallel with wires
connected to terminals 3 and 4.
Detach right side panel from one of the wall controls.
Attach wiring to back of both wall controls (white wires to
terminal #3 screws, wires with stripes to terminal #4 screws).
Follow the same steps as above to mount additional wall
controls panels and wire connections.