Instructions / Assembly
18
11. SYSTEM SET UP
Fig. 41A
Fig. 41
For proper initial operation of the operator, two basic
functions must be set using the initial system programming:
Open Door Position
Close Door Position
Program Remote Control (Transmitter)
Press and hold the “P” button for approximately 3 seconds.
When illuminates, release the button. You are now
ready to set or change the desired adjustment. If no buttons
are pressed within 120 seconds while in programming
mode, the control unit reverts back to operating mode.
TO MAKE OR CHANGE ANY ADJUSTMENT
If no changes are needed at any particular stage, you can keep
the current information and “skip” over a specific adjustment by
pressing the “P” button once. This is useful to know if you want
to change only one setting, without changing any of the other
adjustments. Simply enter the adjustment mode by pressing and
holding the “P” button for approximately 2 seconds, then press
and release “P” repeatedly until your particular adjustment is
reached. This bypasses the unneeded adjustments, and takes you
right to the adjustment you want. When your adjustment or
setting is complete, simply press ”P” as many times as needed to
bypass the remaining steps and exit out of the program,
returning the operator to normal mode.
NOTE: You may exit the System Set Up at any time by pressing
the button “P” for more then 5 sec. The set up programming
can be terminated at any time and from any stage. To do so,
press the “P” button for longer than 5 seconds.
In order to insure a trouble-free programming:
• The door must be in the “CLOSED” position and engaged
to the drive system (rail) before programming the
operator or a system reset is performed.
Overview of the control unit
Display Description
Ready for operation
Door position: CLOSED
Door position: OPEN
Fault message / Maintenance indicator in CLOSED
door position
Photoeye safety system
Remote control
External button
3
Status display
Battery backup system connected
1
2
3
4
5
6
7
8
9
0
Level indicator (Example: Level 2)
Display shows Level 2
1
2
3
4
5
6
7
8
9
0
Menu and parameter indicator
(Displayed Menu 3, Parameter Setting 8)
Minute indicator
1
2
3
4
5
6
7
8
9
0
Times exceeding one minute are shown in
minutes and seconds.
Example: 1.2 = 1 minute + 20 seconds =
80 seconds
Control elements
1
2
3
4
5
6
7
8
9
0
1
2
3
4
5
6
7
8
9
0
LED display
Drive the door in the OPEN direction, increase the
value
Drive the door in the CLOSE direction, decrease
the value
P
Start programming, and save values
Status display
Display Function / Element
4
Warning time indicator (only for programmed
automatic closing)