Instructions / Assembly

32
23-2. ENERGY PACK 100 (BATTERY BACKUP) (cont’)
B
3
1
2
3
4
5
6
7
8
9
0
20 s
P
P
P
P
A
3
20 s
green
red
10.
green
green
Battery Charging
Battery is Low
All Systems are Normal
Fully Charged
Note: New installation
or after an electrical
power outage requires
24 hours to fully charge
Replace batteries
if blinking red LED
persists 24hrs after
power is restored.
red
IMPORTANT:
The battery charges when the garage door operator is
plugged into a working electrical outlet (it has power).
Required charging time for a new installation or
after an electrical power outage is 24 hours.
IMPORTANT:
Instructions for figure “B”
Upon connecting the new BBU
Energy Pack 100 to the operator
and connecting the operator to
main power source as shown in
Step 7. After 20 seconds the
system will automatically recognize
the connection and display a
screen as shown in figure “A”.
Battery Normal Charge Condition
IMPORTANT:
In the event the operator
does not recognize the
connection, the steps in
figure “B” must be
performed to bring the
BBU, Energy Pack 100,
on-line with operator.
Battery Low Charge Condition
1. Press and hold button for 10 seconds.
2. Press and release button until the dashes above the
numbers cover 1-5
3. Press and release the button once.
4. Press and release the button until the dashes underscore 1-7.
5. Press and release button once.
6. Press and release button – Number 2 is blinking
7. Press and release button once.
8. Press and hold button until the word “on” is being
displayed – Number 3 on the screen indicates that the BBU
has been activated.
P
P
To obtain maximum battery life and to prevent
damage, disconnect the battery when the
garage door operator is unplugged for an
extended period of time.
Energy Pack should be replaced every 1-2 years
with normal use, under normal operating conditions.
Replace fuse with Type Littlefuse Blade Fuse
Series 257 rated 15 Amps, 32VDC ONLY
(P/N 72280).