Single Speed Connection with Timer
These steps as outlined below are for connection of the imPower motor to a single
speed timer.
Step 1: Remove the three screws holding the top control enclosure onto the
motor. Carefully lift the top panel and turn it over to expose the inside
of the terminal box.
Step 2: Run the L1, L2, and GROUND wires from the conduit cable through the
threaded opening on the right side of the connection box.
Step 3: Connect the L1 to the terminal block opening directly across from the
ORANGEwire(refertoFigure6).
Step 4: Connect L2 to the block opening directly across from the WHITE wire
(refertoFigure6).
Step 5: Connect the ground to the block
opening directly across from the
GREEN/YELLOW wire (refer to
Figure6).
Step 6: Screw in the conduit connector into
the terminal box on the right side of
the terminal box (shaft facing away
from you).
Always disconnect the main power from the unit prior to servicing the pool
pump lter motor. It is also good practice to conrm the power is o with a
voltage meter
- 1 -
Safety Considerations
The following definitions are used as safety considerations on the
Evergreen IM motor and in this manual. Please read and observe all
of these safety concerns.
SAFETY
SYMBOLS
Installation and service of this motor should be attempted only by
trained service technicians familiar with the Evergreen instructions
and training manual.
This motor should be installed in accordance with accepted practices
and installation instructions, and in compliance with all national and
local codes.