Automation Controller Signal Line Connection
The steps as outlined below are for connection of the imPower motor to an auto-
mationcontroller.TheoptionallowvoltagecableconnectionkitP/N391-200-01
(15’cord)orP/N391-200-02(25’cord)willberequired.
Step 1: Remove the three screws holding the top control enclosure onto the
terminal box. Carefully lift the top panel and turn it over to expose the
inside of the terminal box.
Step 2: Run L1, L2, and GROUND wires from the conduit cable through the
open on the right side of the motor (shaft facing away from you).
Step 3: Connect L1 from the automation
controller to the opening directly
across from the BLACK wire on the
terminalblock(refertoFigure11).
Step 4: Connect the L2 / White to the
opening directly across from the
WHITE wire on the terminal block
(refertoFigure11).
Step 5: Connect the ground to the opening directly across from the GREEN/
YELLOWwireontheterminalblock(refertoFigure11).
Step 6: Screw in the conduit connector into the terminal box on the right side
of the terminal box (shaft facing away from you).
Step 7: Remove the small threaded black
plug on the rear of the terminal box.
Step 8: Pull the cable through the low
voltage conduit connector con-
tained within the kit and tighten
the connector into the appropriate
terminal box threaded hole. Run the
low voltage cable to the automation
control box.
- 1 -
Safety Considerations
The following definitions are used as safety considerations on the
Evergreen IM motor and in this manual. Please read and observe all
of these safety concerns.
SAFETY
SYMBOLS
Installation and service of this motor should be attempted only by
trained service technicians familiar with the Evergreen instructions
and training manual.
This motor should be installed in accordance with accepted practices
and installation instructions, and in compliance with all national and
local codes.
REG7232_EvergreenIM_Reprint.indd 1 4/28/10 2:05:19 PM
Always disconnect the main power from the unit prior to servicing the pool
pump lter motor. It is also good practice to conrm the power is o with a
voltage meter.
Figure 11
Figure 12