Default Reduced Speed Operation:
1. Forastandardsinglespeedtimerconnection,themotorwillrunhigh
speed for the duration of the two hour initial operation. After this time
period, the speed will convert to the new default speed.
2. Foramodiedsinglespeedtimerconnection,themotorwillrunhigh
speed for the duration of the two-minute initial operation. After this time
period, the speed will convert to the new default speed.
3. Foramulti-speedtimer,themotorwillstayathighspeedforthe
remainder of the Circuit 1 time setting. The new default reduced speed
will begin during the second speed Circuit 2 selection time period.
Notes:
1. The motor will run only on high speed during the two-minute window
for automatic default speed changes. There will be no speed change to
indicate initial or new speed settings. The new default reduced speed
is only indicated by the second series of blinking lights as described in
Step 5.
2. Repeat steps 1-6 to revert back to the previous default reduced speed.