Remove the Existing Motor from Pump
Step 1: Loosen and remove the screws holding the seal plate to the pump
housing. Pull the seal plate / motor assembly from the pump housing.
Step 2: Remove the screws holding the diuser to the seal plate and remove it.
Step 3: After conrming that the power has been shut o, remove the electrical
connections from the existing motor. Remove the conduit and connec-
torfromthemotor.Note:theconduitandconnectorwillbere-used.
Step 4: To remove the impeller lock the shaft by placing a wrench or a athead
screwdriverattheopeningintherear.Note:Donotreusetheseal
from the existing motor when installing the imPower motor. Remove
the screws holding the seal plate onto the motor.
Step 5: Remove the pump motor by removing the four bolts holding the motor
to the seal plate of the pump. Also remove the stationary portion of the
seal from seal plate.
- 1 -
Safety Considerations
The following definitions are used as safety considerations on the
Evergreen IM motor and in this manual. Please read and observe all
of these safety concerns.
SAFETY
SYMBOLS
Installation and service of this motor should be attempted only by
trained service technicians familiar with the Evergreen instructions
and training manual.
This motor should be installed in accordance with accepted practices
and installation instructions, and in compliance with all national and
local codes.
REG7232_EvergreenIM_Reprint.indd 1 4/28/10 2:05:19 PM
When servicing the pool pump lter motor, always disconnect the main power
from the unit. It is also good practice to conrm the power is o with a meter.