How-To Guide

CXR-I
Dive
Comput
er
1.6.
BUTTON
OPERATION
CXR-I has four
buttons.
These
buttons all
o
w
you to
access menus
and
change settings
while
in
surface
mode. During the dive
the
y
switch
displays,
call up the
compass
or
the
map function, and allow to display
further
information
on the
computer screen. The
function of each button is identified by a set of
letters
or an icon
placed
just above the
butt
on
itself. In
certain circumstances,
for
ins
t
anc
e
when
erasing
a set
bearing
in the
digit
al
compass
or when calling up the gas
switch
function during a
multigas
dive, a button
c
an
perform
two
tasks, depending
on
whether
it
is
pressed
and
released
or
pressed
and held
f
or
one
sec
ond.
In such
case, there
will be two
groups of
letters
or icons above a
button:
the left
one
corresponds
to the
press-and-release action,
the right one to the
press-and-hold action.
From
the home display you have the
f
ollowing
possible operations (press/press
and hold)
f
or
the
buttons
from left to right (Fig. 1):
1.7.
IN CASE OF EMERGENCY
(ICE)
-
Place
CXR-I at about 15 cm
/
6
inches
from
the tank
module
as shown in Figure
5.
Push
SELECT
and wait until the
pr
ogr
es
s
bar
advances
to the end.
Y
ou
will
either
see
the
message
PAIRING
SUCCESSFUL
or
PAIRING NOT SUCCESSFUL
.
In the
fir
s
t
case
you have
suc
c
es
sfull
y
es
t
ablished
a
connection,
in the
second
you need
t
o
repeat
the
operation,
but you must turn
off
the valve and
depressurize
the
first
s
t
age
completely,
then wait 1 minute
bef
or
e
attempting
again.
CXR-I allows you to
enter information
about
y
ourself,
such as
name, contact
inf
ormation,
emergency number, insurance
policies
and
allergies.
This
information
is
entered
via
the
PC
software
Dive
Organizer.
Alternatively,
it
can also be
entered
via the
Div
er
s
’
Diary Mac
software.
The
first
two lines of the ICE
are
displayed
in the home
display
.
-
1.8.
MOUNTING AND
P
AIRING
OF THE TANK MODULE
(OPTIONAL)
NOT
E
-
When diving with more than one
gas
mixture, tanks
G1
through
G5
must be
set to
increasing
oxygen levels.
Ref
er
to
section
11 for more
information on
multigas diving.
A
tank
module
can only be
paired
to
one
channel
on one CXR-I. If you pair
the
same
tank
module
to a
second channel
on the
same
CXR-I or to a
sec
ond
CXR-
I, the
first
one will be
er
ased.
CXR-I
f
eatur
es
an exclusive
two-way
communication technology through
which
it
can
communicate
with up to 5 tank
modul
es
regarding
tank
pressure
and gas
consumption
information
via
patented
int
erf
er
enc
e-fr
ee
communication.
Each tank
module needs
t
o
be
mounted
on a high
pressure
port of a
fir
s
t
stage
r
egulator
.
In
order
for CXR-I to display tank
pr
es
sure
and gas
consumption information,
you
mus
t
first establish
a
channel
of
communication
between
the tank
module
and CXR-I.
This
is called pairing. This
operation needs
to
be
performed
only once and
ensures
a
permanent
and
interference-free
link
between
the
two
de
vic
es.
-
-
PRE/POST:
enters
PRE dive
mode/ent
er
s
POST
DIVE
mode (only if
there
is
r
emaining
desaturation
in the
computed
tissues);
LOG/PLAN:
enters
the
logbook/enters
div
e
planner mode;
GAS/GF:
enters
oxygen and
helium
setting
menu/displays gradient
factor
settings
t
able;
MENU/BT: goes to main
menu/s
t
arts
bluetooth connection.
After a
successful
pairing of
G1
to
CXR-I,
the
home and the
pre-dive
display will
sho
w
the tank
pressure
in
either
bar or psi. If
t
ank
G1
has not been
paired,
CXR-I will show
an
empty field
instead
of a
pressure
value. If G1
has been
paired
but CXR-I is not
receiving any
signal, it will show
- - - instead
of a
pr
es
sure
v
alue.
-
-
-
NOTE
To
perform
the pairing
operation,
the
t
ank
module must
be
pressurized
to at
l
eas
t
15bar/220psi.
Hence it
must
be
mount
ed
on
a
first stage regulator,
which is
itself
mounted
on a full
scuba
tank and the
v
al
v
e
opened.
NOT
E
During a dive, icons are used to define
the
button function.
From
left to right you will
see
(Fig. 2):
-
The Mares tank
module
has a
range of
appr
o
ximat
el
y
1.5m/5ft.
If a tank
module battery
is weak,
CXR-I
alerts
you with a
screen message
referencing
the
channel designation
assigned
to the tank
module
in
ques
tion.
During a dive, you can ask CXR-I
to
display the
battery status
of the
t
ank
module.
More
information
about this
in
section
8.5.6 and
9.
-
enter compass
mode/ent
er
underwater menu
switch to
graphic display/call up
list of
s
t
ops
change
field in lower
right
corner/initiate
gas
switch
change
field in top right
c
orner/
call up
tissue saturation gr
aph.
/
:
To
mount
the tank
module
on the
first
s
t
age
regulator, first
r
emo
v
e
the high
pressure port
plug, then
screw
in the tank
module
gently by
hand until you feel a
minimum
of
r
esis
t
ance,
then use a 19mm
wrench
to
tighten
it (Fig. 3).
/
:
-
/
:
/
:
NOT
E
Refer to the
dedicated
tank
module manual
f
or
information
on how to
replace
the
battery in
the tank
modul
e.
The dive display is
described
in more detail
in
section 9.
Other icons that might
appear
during a dive
ar
e:
AGF:
allows you to switch
between
the
main
set of GF and the
alternate
set
-
Do not force the tank
module
whil
e
holding it by the
plastic
c
ap.
Do not
o
v
ert
orque
while using
the
wrench:
the o-ring seal is
assured as
soon as you feel the
first resistance. The
only
reason
for using a
wrench
to
tight
en
a bit more is to
pr
e
v
ent
the tank
modul
e
from
unscrewing
itself over
time.
-
NOTE
-
Y
ou
do
NOT
need to
repeat
the
pairing
procedure
after a
battery replacement in
the tank
modul
e.
:
calls up deco
summary
t
abl
e.
allows to set a
bearing (press) or
erase
a set
bearing (press
and
hold)
(COMPASS)
makes stopwatch appear
(COMPASS)
makes stopwatch disappear
(COMPASS)
restarts stopwatch
(COMPASS
and
DIVE,
only if
stopwatch
on
scr
een)
exit from predive
mode
return
to
standard
display (COMPASS,
TISSUE GRAPH,
MAP,
GAS
TABLE).
-
Y
ou
do
NOT
need to
repeat
the
pairing
procedure
if the
battery
in CXR-I
is
compl
et
el
y
empty.
Y
ou
do
NOT
need to
repeat
the
pairing
procedure
after
upgrading
the
firmwar
e
in your
CXR-I
.
:
The Mares tank
module communicates
via
radio frequency
with CXR-I. For
bes
t
transmission,
we
recommend positioning
the
tank
module
as
described
in Figure
4.
To pair the tank
module
with the
CXR-I,
proceed
as
f
ollo
ws:
-
:
:
:
-
Open the tank valve to
pressurize
the
t
ank
module.
You
now have two
minutes
t
o
perform all
steps
listed
bel
o
w;
Go into SET
DIVE/GAS
INTEGRA
TION/P
AIR
DEVICES
Choose the
channel
that you wish to
as
sign
to
the device (if this is your only tank
modul
e
for single gas diving,
choose
G1.
G2
thr
ough
G5
are used for
multigas
dives. Mor
e
information
on this in
section 11);
1.9.
TURNING OFF
CXR-I
CXR-I
turns
off
aut
omatic
all
y
after 3
minut
es
without
operation
when in
surface
mode
and
after 10
minutes
without
operation
when
in
pre-dive
mode.
From
the main
menu,
y
ou
can
also turn it off
manuall
y
by
selecting the
BUTTON LOCK
ic
on.
:
-
:
-
6