Specifications

30.4 [1.20]
27.0 [1.06]
LOCK
WASHER
SEE NOTE 1
LOCKNUT
THRUST
WASHER
SEALING
GASKET
7/8-16UN
49.3 [1.94]
32.7 [1.29]
7/8-16UN
FEMALE END VIEW
MALE END VIEW
73.0 [2.87]
37.3 [1.47]
7/8-16
UN
7/8-16
UN
28.0 [1.10]
Ø26.0 [1.02]
Ø26.0 [1.02]
17.5 [0.69]
19.2 [0.76]
17.5 [0.69]
7/8-16UN
74.5 [2.93]
37.4 [1.47]
18.7 [0.74]
7/8-16UN
Ø26.0 [1.02]
Ø26.0 [1.02]
Mini Gender Changers
Mini Bulkhead
Feed-Thru
N2KMeter
Specifications
Specifications
Specifications
Products Products
Products
MECHANICAL
Contact Carrier Mat/Color: Thermoplastic PUR/Blue-Gray
Housing Mat/Plating: Brass/Nickel
Contact Mat/Plating: Brass/Gold
Gasket Material: Nitrile (Buna N)
Accommodates Wall (thick):
.040” (1.0 mm) to .875” (22.2 mm)
ELECTRICAL
Voltage Rating: 600 V
Max Amperage: 9.0 Amps
Number of Conductors: 5x22 AWG
ENVIRONMENTAL
Protection Class: IEC IP67
Temperature Range: -40°C to 105°C (-40°F to 221°F)
APPROVALS
NMEA: NMEA 2000
®
Approved
IEC: IEC 61162-3
MECHANICAL
Power Supply: Network 7 - 30v DC < 90MA
Batteries 2 X AA Alkaline Batteries
6 Hours Of Operation Approx.
1 Year Data Retention
Connectors: Micro Connector
Band Rates: 125k, 250k and 500k (Auto-detect)
Analog Accuracy: Bus Power±100mv, Bus Signal±20mv
Analog Range: Bus Power 0 to 25v with over/under
Range Indication Bus signal -5 To 10v
with over/under range Indication
Analog Sample Rate: Bus Power 1 Khz Bus Signal Ideal
Sample Pt±250ns
Signal Error Threshold: NMEA 2000® Spec for Network Power
Bus Load Measurement: Detects Bus Idle In Real Time
Bus Message
Rate Measurement: Detects 100% of Individual Can
Frames in Real Time
Error Rate Measurement: Detects 100% of Individual Error
Frames in Real Time
APPROVALS
NMEA: NMEA 2000® Approved
MECHANICAL
Molded Body Mat/Color: Thermoplastic PUR/Blue-Gray
Contact Carrier Mat/Color: Thermoplastic PUR/Blue-Gray
Contact Mat/Plating: Brass/Gold
Coupling Nut Mat/Plating: Brass/Nickel
ELECTRICAL
Rated Current: 9.0 Amps
Rated Voltage: 600 V
ENVIRONMENTAL
Protection Class: IEC IP67, NEMA 1,3,4,6P – NM-NM
IEC IP67, NEMA 1,3,4,13 – NF-NF
Temperature Range:
-40°C to 70°C (-40°F to 158°F) – NM-NM
-40°C to 55°C (-40°F to 131°F) – NF-NF
APPROVALS
NMEA: NMEA 2000
®
Approved
IEC: IEC 61162-3
PART NUMBER DESCRIPTION
BHF-NM-NF Mini Bulkhead Feed-Thru
PART NUMBER DESCRIPTION
N2KMETER-01 Diagnostic Meter w/1m Micro Cordset
PART NUMBER DESCRIPTION
NM-NM Mini Gender Changer (Male/Male)
NF-NF Mini Gender Changer (Female/Female)
1. Plug in and set N2KMeter rotary switch to “autosearch”
2. Identify network health
• Happy face = healthy
• Neutral face = nominal
• Sad face = faulty
3. Scroll through faults. Refer to user manual
to link these faults to most likely network
problems or freeze and lock settings for review
back at the shop by an NMEA 2000® expert.
1. Scroll through NMEA 2000® parameters for each active NMEA
2000® node (mac id)
• Communication errors (rate, cumulAtive #)
• Bandwidth (% of full usage)
• Power supply and shield voltages
• Data bit quality (dominant, recessive, +, -,
differential voltage, cmv)
2. Check values (both numeric and icons)
• Happy face = within spec
• Neutral face = very close to limit
• Sad face = out of limit
3. Refer to user manual to link these faults to most
likely network problems
Electrician Mode (Simple)
Expert Mode (Advanced)
MINI